Specification
1.The parameters as shown in above table are measured at ambient temperature of 20
℃
.
2.The noise value is measured 1.5m far from the product at angle of 45° below the air outlet.
The air outlet is the maximum value.
3.Because the above-mentioned velocity is measured in test laboratory where it’s empty,
without air flow and obstacle, after actual installation the velocity may vary depends on
different service environment.
Voltage: 1 phase 220V
Voltage: 1 phase 220V
Frequency: 60Hz
Frequency: 50Hz
High Low High Low High Low High Low High Low
3009UA
3009DA
3009GA 10.5 8.5 76
70
0.35 0.32 1100 920 48.5 45
B
900
12.5
4009UA
4009DA
4009GA 12
10 110 94
0.5
0.43 1340 1190 54.5 51
B
900
13.5
3012UA
3012DA
3012GA 9.5 8
94
85
0.43 0.4
1400 1270 48.5 44.5
B
1200 15
4012UA
4012DA
4012GA 12
10 126 105
0.59 0.49 1700 1530 52.5 48.5
B
1200 16
3015UA
3015DA
3015GA 10.5 9.5 131 110
0.59 0.5
2000 1800 51.5 48
B
1500 18.5
4015UA
4015DA
4015GA 13
10 177 147
0.81 0.68 2450 2000 56
52
F
1500 18.5
Insulation
Class
Length
mm
Weight
k
g
Model
Outlet
Velocity
m/s
Power
Consumption
W
Current
A
Air Volume
m³/h
Noise
dB(A)
High Low High Low High Low High Low High Low
3009UA
3009DA
3009GA 10.5 8.5 92
78
0.42 0.36 1100 900 49.5 45
B
900
12.5
4009UA
4009DA
4009GA 12
10 141 111
0.64 0.51 1340 1100 55.5 51
B
900
13.5
3012UA
3012DA
3012GA 9.5 8
109 94
0.51 0.46 1400 1250 48.5 44.5
B
1200 15
4012UA
4012DA
4012GA 12
10 153 118
0.7
0.55 1700 1450 52.5 48.5
B
1200 16
3015UA
3015DA
3015GA 10.5 9.5 150 118
0.68 0.54 2000 1750 51.5 48
B
1500 18.5
4015UA
4015DA
4015GA 13
9.5 220 160
1.01 0.74 2300 1780 56
52
F
1500 18.5
Insulation
Class
Length
mm
Weight
k
g
Model
Outlet
Velocity
m/s
Power
Consumption
W
Current
A
Air Volume
m³/h
Noise
dB(A)
High Low High Low High Low High Low High Low
3009UA
3009DA
3009GA 10.5 9
86
80
0.37 0.35 1150 960 50.5 47.5
B
900
12.5
4009UA
4009DA
4009GA 12.5 10.5 122 100
0.51 0.43 1360 1200 56.5 53.5
B
900
13.5
3012UA
3012DA
3012GA 10
8.5 107 95
0.46 0.43 1500 1320 50.5 47
B
1200 15
4012UA
4012DA
4012GA 12.5 10.5 139 110
0.6
0.49 1800 1580 54.5 51
B
1200 16
3015UA
3015DA
3015GA 11
10 145 115
0.6
0.5
2100 1850 53.5 50.5
B
1500 18.5
4015UA
4015DA
4015GA 13.5 10.5 200 160
0.86 0.68 2500 2050 58
54.5
F
1500 18.5
Weight
k
g
Model
Outlet
Velocity
m/s
Power
Consumption
W
Current
A
Air Volume
m³/h
Noise
dB(A)
Insulation
Class
Length
mm
Voltage: 1 phase 240V Frequency: 50Hz
20
NOTE
Installation
height
(
m
)
3m
3m
3m
4m
4m
4m
Installation
height
(
m
)
3m
3m
3m
4m
4m
4m
Installation
height
(
m
)
3m
3m
3m
4m
4m
4m