Multiple products operation in group
Wiring diagram
Wiring for operation of multiple products in parallel
Power supply cord
●
Please purchase necessary parts following with local electrical requirements.
■
Please follow with below figures to conduct the wiring.
■
Remote control series
■
Sensor series
■
Basic series
■
Please select the switch of whose capacity has 1.2
~
1.5 times of power
supply cord. When multiple products operate.
■
Earth leakage breaker protector should be equipped, otherwise it may
cause an electrical shock.
■
The number of interlocking operation is not more than 6.
11
Red
Black
White
(
H
)
Yellow
(
L
)
Yellow
White
Black
Capacitor
Mo
to
r
Switch
Power
TE
RMI
N
A
L
Sourc
e
Orange
Blue
Double Pole Switch
Customer Provide
(Contact Point Separate Distance Over 3mm)
Green/Yellow
N
L
N
L
Brown
9P
Buzzer
SWITCH PCB
Receiver
Red
Lamp
Lo
Red
Lamp
Hi
Blue
Po
we
r
So
ur
ce
Brown
Blue
Brown
N
L
Green/Yellow
Black
Black
N
L
Yellow
Switch
E
Switch
E
White
White Yellow
(L)
(H)
Red
Capacitor
Motor
M
Orange
Terminal
MAIN PCB
TAB-L
TAB-N
1P
9P
1P
5P
1P
5P
1P
Double Pole Switch
Customer Provide
(Contact Point
Separate Distance
Over 3mm)
Magnet
3P
3P
SWITCH PCB
Blue
Po
we
r
Sou
rce
Brown
Blue
N
L
Brown
Green/Yellow
Black
N
L
Black
Yellow
Piano
switch
White
White Yellow
(L)
(H)
Red
Red
Capacitor
Motor
M
Orange
Terminal
Common
Open TAB-L
TAB-N
1P
1P
5P
5P
1P
1P
Double Pole Switch
Customer Provide
(Contact Point
Separate Distance
Over 3mm)
WARNING