- 11 -
Programming on
Using the manual programming mode, we will program the following
●
Manual Program Mode
parameters on course No.24 to store the example.
Ex. Co-Cr Alloy for Metal Plate
(
℃)
Star Temp.
2282
1250
(
℃)
Melt Temp.
2660
1460
Melt Time
6 min. 0 sec.
Cast Timing
- 0.3 sec.
Cooling Time
2 min. 0 sec.
Crucible
Ceramic
1. Press the
button to adjust the course display to read
.
Program Course
∧∨
2. Press the PROGRAMMING button.
The Program lamp is illuminated and the Start Temp. is blinking.
3. Press the
button to display
and press the OK button to
Start Temp.
∧∨
store the Start Temp.
The lamp of Melt Temp is blinking.
4. Press the
button to display
and press the OK button to
Melt Temp.
∧∨
store the Melt Temp.
The lamp of Melt Time is blinking.
5. Press the
button to display
.
and press the OK button to
Melt Time
∧∨
store the Melt Time.
The Cast lamp is blinking.
6. Press the
button to display
.
and press the OK button to
Cast Timing
∧∨
store the Cast Timing.
The lamp of Cooling Time is blinking.
7. Press the
button to display
.
and press the OK button to
Cooling Time
∧∨
store the Cooling Time.
The selection lamps of crucible type are blinking.
8. Press the
button to choose the desired crucible type.
Choice of Crucible Type
∧∨
We recommend you to refer to the casting manual provided for advice which type of
crucible to use with your alloy.
Note The maximum temperature programmable for carbon crucible is 2642
1450
.
)
(
℃)
9. Press the OK button to store the program and program check is
available. If you find any error in the program storage, the error is
modifiable in the same program method listed above.
10. Once the correct program storage is confirmed, press the PROGRAMMING
button to exit the Manual Program Mode.
The lamp of Start Temp is blinking and the unit is heating up toward the Start Temp.
Note When you do not continue further casting, we recommend you to turn the power off
)
or to select a blank programmed course, otherwise the unit will unnecessarily
continue heating up to the start temp.
is displayed when you exited the manual program mode, one of the
Note If
)
program parameters stored is invalid. The relative invalid program parameter on the
process indicator will blink and we recommend you to correct the invalid program as
described in the
Program Check and Modification
below.
「
」
●