5.
Secure excess tubing to prevent interference with patient mobility.
6.
If desired, place the therapy unit into the carrying case. Ensure
display is visible through the opening in the carrying case.
7.
The carrying case comes with both an adjustable strap and belt clip
for carrying. The belt clip and additional clips on each side and at
the bottom of the carrying case provide a place where excess tubing
may be wrapped and stored to help prevent/minimize tripping and
strangulation.
CAUTION: Do not wear or wrap strap around neck. Do not wrap
tubing around neck.
UNIT TROUBLESHOOTING
If the PREVENA PLUS™ 125 Therapy Unit will not power on, make sure batteries are charged (see
Battery Charging section). If the therapy unit still will not turn on, contact KCI.
THERAPY LIFE INDICATORS
NOTE: Grey represents green indicators and black represents yellow indicators.
The therapy life indicators provide a visual display of the seven day therapy life cycle and the therapy
life remaining. When therapy begins all seven green LEDs are illuminated. During therapy, after each
24-hour period an indicator will turn off. When eight hours of therapy time remains, the last indicator
will illuminate with both a green and yellow LED simultaneously. When therapy time is about to
expire, the last indicator will illuminate with a yellow LED and an alert will sound for approximately
two minutes, then the therapy unit will shut off.
At the end of therapy, the therapy unit must be replaced with a new unit or alternative therapy must
be used. Patients should be instructed to contact the treating physician or caregiver if therapy unit
turns off and cannot be restarted before therapy is scheduled to end.
NOTE: Once therapy is on for one hour non-stop, the seven day lifespan countdown begins and
continues even if the unit is turned off.
Wrap
tubing
around
clips
Begin
Therapy
4 Days
Left
2 Days Left
1 Day Left
8 Hours
Left
Therapy ended.
Therapy unit will
shut off.
Содержание PREVENA PLUS
Страница 381: ...EL PREVENA PLUS PREVENA PLUS CUSTOMIZABLE SENSAT R A C...
Страница 382: ...KCI KCI KCI KCI KCI KCI KCI...
Страница 384: ...408 408 408 PREVENA PLUS 125 409 410 PREVENA PLUS 410 PREVENA PLUS 125 411 416 417 495...
Страница 391: ...391 1 2 3 4 1 5 PREVENA PLUS CUSTOMIZABLE 8 cm 3 1...
Страница 392: ...392 6 7 8 9 2 10...
Страница 393: ...393 1 2 3 4 5 PREVENA PLUS CUSTOMIZABLE 8 cm 3 1...
Страница 394: ...394 6 7 8 1 2 3 4 5 PREVENA PLUS CUSTOMIZABLE 8 cm 3...
Страница 395: ...395 1 6 7 8 PREVENA PLUS CUSTOMIZABLE 3 cm 1 2 1 KCI KCI 3 cm 1 2 2 1 KCI 1 KCI 3 KCI KCI 3 cm 1 2 4 1 KCI 5 2 KCI...
Страница 396: ...396 6 7 KCI KCI 1 2 3...
Страница 399: ...399 1 PREVENA PLUS PREVENA PLUS CUSTOMIZABLE 2 PREVENA PLUS 125 LED 3 4 SENSAT R A C 3 X...
Страница 400: ...400 5 6 7 PREVENA PLUS 125 KCI LED 24 LED LED 4 2 1 8...
Страница 401: ...401 PREVENA PLUS PREVENA PLUS 125 15...
Страница 402: ...402 ID LED 15 LED 15 LED LED LED 15...
Страница 403: ...403 1 2 3 KCI 1 2 3 2 2 2 2...
Страница 404: ...404 PREVENA PREVENA PLUS 125 3 X...
Страница 408: ...408 PREVENA PLUS 125 PREVENA PLUS 1 2 3 1 2 3 PREVENA PLUS CUSTOMIZABLE...
Страница 409: ...409 PREVENA PLUS 125 KCI KCI KCI KCI KCI PREVENA PLUS 25 110 kPa 27 5 kPa 110 kPa PREVENA PLUS PREVENA PLUS 125 KCI KCI...