Connections
Connecting the mains voltage
DANGER!
Live components
Risk of fatal injury due to electric shock
when touching live parts.
- Switch off mains voltage.
- Protect against re-connection.
Both the power supply and the related connection
work must comply with national standards, e.g. those
set up by VDE in Germany. The connection work
must only be performed by qualifi ed expert staff.
The connection to the 400 V mains must be protected
by fuses. Their specifi cations are listed in the chapter
“Technical data”. A residual current-operated circuit
breaker (RCD) with short time delay is absolutely
required. KBL AG recommends the following type:
KBL 3200 0770 00 (type (Typ ABB F 204 A - 40//0,03
AP-R). Should the operation of the tanning unit cause
any interference in the power supply network, e.g.
with ripple-control systems (TRA), consult your power
supply company to have corresponding blocking
elements (audio frequency suppressors) installed.
Figure: mains connection
Connecting an external audio
source
When connecting an external audio source, pay
attention to the correct polarity.
Figure: connecting external audio
R-
green
Wiring on the audio equipment’s side
yellow
white
brown
R+
L-
L+
Level adjustment
The voice/audio system components are built
into the base part (in the head area) of the tanning
unit. The total level adjustment is carried out via a
potentiometer (see arrow) that is located on the audio
switch circuit board.
Figure: audio switch circuit board
O p e r a t i n g I n s t r u c t i o n s
|
mon amie
9