Tubes
DISMANTLING
Proceed as follows in order to be able to clean or
replace tubes:
Procedure
Fig.
1
Dismantle the canopy, bed and side
panes.
31.1
31.2
31.3
2
Remove the tube covers in the facial and
foot areas.
CLEANING CYCLE
In order to preserve the tanning effect, we recommend
cleaning the tubes with warm water and a chamois
after approx. 200 hours of operation. Do not use any
cleaning agents that are aggressive or contain alcohol.
REPLACEMENT CYCLE
Only replace tubes with those listed on the device.
When installing the tubes, make sure that the
inscription is visible. In this position, the refl ector of
the tube is at the back. If your tanning unit is equipped
with CPI, you must carry out a reset after each tube
replacement. Reset the operating hours counter of
the tubes after each replacement.
Unit lighting
The unit is lighted (decorative lighting) by means of
three fl uorescent tubes
② ③ ④
as well as high-
performance LED‘s
①
in the canopy of the unit.
Figure 32.1: mon amie unit lighting
②
③
④
①
Position
Item no
①
High-performance
LED’s in unit canopy.
②
Fluorescent tube
under the bed pane.
3230074783
③
The front fl uorescent
tube of the canopy.
3230074784
④
Fluorescent tube on
the rear wall.
3230074784
In case of defective high-performance LED’s, these
can only be replaced by qualifi ed specialists. Get in
touch with the Service organisation in this case.
The front canopy fl uorescent tubes
③
are changed
just like the other canopy tubes.
O p e r a t i n g I n s t r u c t i o n s
|
mon amie
32