background image

 

 

WESII User Manual 

 

 

 

 

 

Manual-WESII-Rev1205A 

Copyright © KBC Networks 2012 

 Page 9 of 48

 

         

www.kbcnetworks.com 

 

                      

 

 
 
 

           

POE +

P

o

w

e

r

O

U

T

IN

Local Power
Remote Power

PIM Top View

  

        

 

PIM Side View (Power and Output)

   

 

PIM Side View (Input)

 

 

Note:

 KBC Networks’ WESII units are mid-span compliant and must be powered 

using the supplied power injection module. 

 

2.3.4

 

RF Module LED Description 

 

1.

 

Status/Signal Strength Indicator – 40 RSSI 

2.

 

Signal Strength Indicator – 30 RSSI 

3.

 

Signal Strength Indicator – 20 RSSI 

4.

 

Signal Strength Indicator – 10 RSSI 

5.

 

Ethernet Link Activity 

6.

 

Power 

 

 

 LED Boot Up Process  

2.3.4.1

 

Upon connection of an Ethernet cable from the PIM to the unit, the Power LED 
6 will light. 

 

After 1 second RSSI LEDs 1, 2 & 3 illuminate.  

 

RSSI LEDs 1, 2 & 3 then go off. 

 

After 5 seconds the Ethernet Link Activity LED 5, illuminates. 

 

At the same time the Signal Strength Indicator, LED 1 flashes for 
approximately 2 seconds. 

 

LEDs 1 & 5 then switch off. 

 

LED 5 comes on again and flashes intermittently showing that a connection is 
established. 

 

After approximately 1 – 2 minutes RSSI LEDs 1, 2, 3 & 4 will light depending 
on the level of signal strength.   

 

Note:

 WESII units with EMEA firmware set to frequencies between 5600 – 5650MHz 

and any channels that overlap these frequencies may take up to 13 minutes to 
connect due to the Channel Availability Check (CAC) time requirement of ETSI 
Dynamic Frequency Selection (DFS). See section 6.4 for further details.

 

 

1  2  3  4  5  6 

2

1.Power – Power supply input 
2.OUT – Connect to the WESII unit 
3. IN – Connect to the Ethernet device 

Содержание WESII-KT

Страница 1: ...WESII Wireless Ethernet System User Manual WESII KT WESII AA xx Series WESII AB xx Series WESII AC xx Series...

Страница 2: ...he WESII Graphical User Interface GUI 17 3 2 Menu Options 18 4 TROUBLESHOOTING 38 4 1 Visual Inspection 38 4 2 Test Cable Connections 38 4 3 GUI Tools 38 4 4 Contact KBC Technical Assistance 39 5 WARR...

Страница 3: ...AC Address lock Additional Ptp Host APs can be deployed using a separate frequency and MAC Address lock with the second Client MAC Address locked into the second WESII Host AP in the environment As wi...

Страница 4: ...ernal antenna options The external antennas can be either omni directional or directional MIMO antenna types that are higher gain than are available in the integrated antenna WESII kits The external a...

Страница 5: ...r static selectable Dynamic Frequency Selection ETSI DFS Power Output 23dBm max1 Transmit Power Control ETSI TPC Channel Capacity Selectable 5 20 or 40MHz Modulation OFDM Receive Sensitivity Tolerance...

Страница 6: ...tion Wall mount or pole mount Environmental Operating Temperature 40 74 C 40 165 F Storage Temperature 40 90 C 40 194 F Operating Humidity 5 to 95 non condensing Connectors 10 100 Electrical 1 x RJ45...

Страница 7: ...er ordered Please contact you dealer or distributor if a part is missing or damaged within 10 days of receiving the products 2 2 Configurations Products are available in either integrated antenna or e...

Страница 8: ...ear view 1 Patch antenna cover 2 Serial number label 3 Internal RF module enclosure 4 Status LEDs See section 2 3 4 for description 5 LAN port RJ45 6 Mounting block 7 Reset to default button 1 Antenna...

Страница 9: ...ght After 1 second RSSI LEDs 1 2 3 illuminate RSSI LEDs 1 2 3 then go off After 5 seconds the Ethernet Link Activity LED 5 illuminates At the same time the Signal Strength Indicator LED 1 flashes for...

Страница 10: ...and password admin admin to access the GUI Disable any other Network Interface connection including the laptop PC WiFi access that is not being used to access the WESII RF Host AP or Client 4 Select...

Страница 11: ...p Host AP can connect to one Client MAC Address only whereas the Ptmp Host AP can connect to multiple Clients If a Host AP is being replaced the Clients with which it is required to communicate must b...

Страница 12: ...unit to the pole Up Down Alignment offers one position when using the pre fabricated channel lock grooves on the swivel brackets Directional antennas may require additional up down alignment angles th...

Страница 13: ...e Ethernet device cannot exceed 100m 325 feet however the PIM can be located anywhere along the overall 100m of cable KBC Networks recommends shielded Ethernet cables for the cable connecting the PIM...

Страница 14: ...illuminated The WESII unit s power LED should be green provided the cable into the LAN port is seated properly If multiple Clients connect to one multipoint Host verify all Clients are on the same fre...

Страница 15: ...ction 3 for further details To get to this information first connect to the RF modules via their respective IP addresses see section 3 using a web browser from a laptop connected to the WESII In the s...

Страница 16: ...is required for max RSSIs Note In some cases depending on the physical and RF environment a useable throughput rate may not be possible See section 4 4 for technical support contact information 2 4 9...

Страница 17: ...erify the green LED illuminates on the PIM The right two green LEDs of the WESII unit LEDs 5 and 6 should also light up indicating power and link activity see section 2 3 4 for expected LED status Due...

Страница 18: ...orks 2012 Page 18 of 48 www kbcnetworks com 3 2 Menu Options The WESII has six menu options Status Services System Basic Network Basic Wireless Advanced Wireless 3 2 1 Status Information The initial p...

Страница 19: ...TEM menu System Time This is the internal clock of the device This is not the actual time but is used for the scheduled reboot function found in the SYSTEM page Status Version 3 2 1 2 The Version scre...

Страница 20: ...her the unit is either set as a Client or Host AP Note Host APs and Clients are pre set in the factory and cannot be changed MAC Each Ethernet device has a unique MAC Media Access Control address This...

Страница 21: ...hesis showing the RSSI s for the vertical 92 and horizontal 91 portions of the radio ie the 2x2 function of the MIMO The vertical and horizontal RSSI figures can be used if two separate directional an...

Страница 22: ...r options include HT5 and HT20 The larger the bandwidth the lower number of channel options available to use Local AP Statistics The transmitted and received data packets over the RF connection are re...

Страница 23: ...l reboot When enabled the system will begin pinging the IP entered after the given interval and will function as configured It must be configured to wait for a particular number of non responses typic...

Страница 24: ...mits down time it may only mask the greater environmental problems at the site KBC Networks recommends trouble shooting all system and connection issues before resorting to the ping watchdog tool Note...

Страница 25: ...k The sample IP above is a valid IP on the 192 168 1 subnet on the network All five attempts replied indicating that the connection to 192 168 1 15 from the WESII unit which performed the ping is esta...

Страница 26: ...t Note The internal clock cannot be set to match real time Services SNMP Set Up 3 2 2 4 The system is compatible with SNMP version 2 3 2 3 System Configuration The System page allows certain configura...

Страница 27: ...3 2 3 2 In this menu option the unit can be given a customized name this is then displayed in the STATUS page Example If a WESII Client is at camera 2 the host name could be Camera 2 or the position o...

Страница 28: ...if required It is recommended that a backup of the WESII configuration is carried out in the event a replacement is necessary or if a restore to defaults is required 1 Click on Back Up 2 The web brow...

Страница 29: ...kbcnetworks com Note if configurations such as a LAN configuration or username password are lost the unit may need to be restored to defaults using the hard reset button on the bottom of the unit case...

Страница 30: ...0 No Gateway IP Interface Access Username admin Interface Access password admin Hostname AP for the Host AP CLIENT for the Client Remote Client Lock to MAC 00 00 00 00 00 00 Local AP ESSID KBC WESII C...

Страница 31: ...the LAN IP Netmask and Gateway IP using an available IP on the network KBC Networks recommends obtaining valid unused IPs from the network administrator if the units will reside on the network The WE...

Страница 32: ...ess Mode is an Access Point In the AP mode the unit will connect with remote Client units with the same SSID and Country Code and channel width Remote Client Lock to MAC Single point to point Host APs...

Страница 33: ...be available for static selection and power output will also be tailored to the regulations of the local country If using an external antenna use only the power output regulated per dB gain of the an...

Страница 34: ...n EMEA firmware versions if the unit is not set to Auto and radar DFS is detected on the selected channel the link will be disconnected and the unit will not automatically search for another channel t...

Страница 35: ...er RSSI of other equipment and greater chance for interference if operating on that channel Transmit Power The Transmit Power option is only available on units with US firmware The maximum transmit po...

Страница 36: ...figured to the security WPA2 and cipher type AES is default configuration selected The SSID will appear in the computer s available APs list unless Hide SSID is selected Once the WESII Host AP is sele...

Страница 37: ...Rev1205A Copyright KBC Networks 2012 Page 37 of 48 www kbcnetworks com Advanced Wireless Other Settings 3 2 6 2 The following are the default RSSI LED configurations These parameters can be changed to...

Страница 38: ...ESII units operating with EMEA firmware may take longer times to connect on certain frequencies see section 6 4 for details 4 2 Test Cable Connections 4 2 1 Determine Link Activity Obtain an IP locati...

Страница 39: ...upport kbcnetworks com 24hr availability response time varies HAWAII ALASKA GUAM PR OTHER US TERRITORIES 949 297 4930 Monday Friday 7am 5pm Pacific Time techsupport kbcnetworks com 24hr availability r...

Страница 40: ...osure to moisture and circuit modification b SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SERVICING OR R...

Страница 41: ...the equipment Excessive or insufficient current or voltage can cause extended trouble shooting or even damage that could negate its warranty The power supply cable should not be modified extended due...

Страница 42: ...cal band is documented in FCC Rules Part 15 247 It is the responsibility of the individuals designing and implementing the radio system to ensure compliance with any pertinent FCC Rules and Regulation...

Страница 43: ...ty Directive 89 336 EEC issued by the Commission of the European Community Compliance with this directive implies conformity to the following European Norms in brackets are the equivalent internationa...

Страница 44: ...ns 5555 2 mins 5560 2 mins 2 mins 2 mins 5565 2 mins 5570 2 mins 2 mins 5575 2 mins 5580 2 mins 2 mins 2 mins 10 mins 5585 2 mins 5590 2 mins 2 mins 5595 2 mins 5600 10 mins 10 mins 10 mins 5605 10 mi...

Страница 45: ...required to ensure an ideal environment Therefore it is not possible to guarantee a successful application based on a drawing application note distance calculation quote or other type of material that...

Страница 46: ...roduct For EU Directive 2002 95 EEC WEEE Tools required No 1 Phillips screwdriver No 2 Phillips screwdriver Steps for disassembly 1 Remove Serial Label adhesive 2 Remove cover screws attaching top cov...

Страница 47: ...p www gnu org licenses licenses html The Licenses allow you to freely copy modify and redistribute that software without any other statement or documentation from us For at least one 1 year from the d...

Страница 48: ...ica 25691 Atlantic Ocean Drive Suite 3B Lake Forest CA 92630 U S A Americas Phone 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA KBC Networks Ltd Barham Court Teston Maidstone Kent ME18 5BZ U...

Отзывы: