2 0 H a M e s i l a S t . , N e s h e r 3 6 8 8 5 2 0 , I s r a e l
P O B 2 5 0 0 4 , H a i f a 3 1 2 5 0 0 1 , I s r a e l
T e l : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 0 0 F a x : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 1 1
Page no. 14 | Configuration Interface
6.3
Acquisition Control
The Acquisition stream control section describes settings and state for data generation (commands and stream).
Acquisition can also be controlled trough executing the relevant commands from this category
Figure 5 – Acquisition Control category in GenICam Browser
6.3.1
Acquisition Control XML parameters
Parameter
Description
Gen<i>Cam name
Type
Possible values
Remarks
Value
Gen<i>Cam name
Gen<i>Cam Category: AcquisitionControl
Acquisition
Reset
Resets the image acquisition
logic and counters
AcquisitionReset
Command
1 - Activate
Acquisition Start Starts the Acquisition of the
device
AcquisitionStart
Command
1 - Activate
Acquisition Stop Stops the Acquisition of the
device at the end of the
current Frame
AcquisitionStop
Command
0 - Activate
Frame Rate Max Acquisition rate maximum
value
AcquisitionFrameRateMax
Float
In units of Hz
Frame Rate
Controls the acquisition rate at
which the frames are captured
AcquisitionFrameRate
Float
≥ 1
In units of Hz
Exposure Mode Sets the operation mode of
the Exposure
(or shutter)
ExposureMode
Enumeration
0x00
Timed
0x01
TriggerWidth
Exposure Time
Max
Exposure time maximum value ExposureTimeMax
Float
In units of
microseconds (us)
Exposure Time Sets the Exposure time when
ExposureMode is Timed
ExposureTime
Float
≥ 1.0
In units of
microseconds (us)
See remark (1)
Trigger Selector Selects the type of trigger to
configure
TriggerSelector
Enumeration
0
FrameStart
Trigger Mode
Controls if the selected trigger
is active
TriggerSoftware
Enumeration
0x00
Off
0x01
On
Table 6 – Acquisition Control parameters