Page no. 25 | Configuration Interface
6.6
Pixel Correction Control
The pixel correction control allow compensating any sensor dead pixel by averaging adjacent pixels.
The Dark and Flat field correction algorithm helps to solve issues with fixed pattern noise, usually originates from
the sensor.
Figure 17 – Pixel Correction Control category in GenICam Browser
6.6.1
Pixel Correction Control XML Parameters
Parameter
Description
Gen<i>Cam name
Type
Possible values
Remarks
Value
Gen<i>Cam name
Gen<i>Cam Category: PixelCorrectionControl
Defect Pixel
Correction
Enable
Enable the Defect Pixel
correction algorithm
DefectPixelCorrectionEnable
Boolean
0 - false
1 - true
Defect Pixel
Selector Max
Total number of defect pixels
to be corrected
DefectPixelSelectorMax
Integer
Defect Pixel
Selector
Total number of defect pixels
to be corrected
DefectPixelSelector
Integer
(Selector)
Defect pixel X
coordinate
Configure defect pixel X
coordinate
DefectPixelX
[DefectPixelSelector]
Integer
Min: -1
Max
:
SensorWidth
Defect pixel Y
coordinate
Configure defect pixel Y
coordinate
DefectPixelY
[DefectPixelSelector]
Integer
Min: -1
Max: SensorHeight
Defect Pixel
Remove
Remove the defect pixel
determined by
DefectPixelWriteX and
DefectPixelWriteY
DefectPixelRemove
[DefectPixelSelector]
Command
1 - Activate
Dark Field
Correction
Enable
Enable the Dark Field
correction algorithm
DarkFieldCorrectionEnable
Boolean
0 - false
1 - true
Flat Field
Correction
Enable
Enable the Flat Field
correction algorithm
FlatFieldCorrectionEnable
Boolean
0 - false
1 - true
Field Calibration
Mode
Sets the operation Field
Calibration mode
FieldCalibrationMode
Enumeration
(Selector)
0
Dark
1
Flat
Field Calibration
Start
Activates the Field Calibration FieldCalibrationStart
[FieldCalibrationMode]
Command
1 - Activate
Table 14 – Pixel Correction Control parameters