2 0 H a M e s i l a S t . , N e s h e r 3 6 8 8 5 2 0 , I s r a e l
P O B 2 5 0 0 4 , H a i f a 3 1 2 5 0 0 1 , I s r a e l
T e l : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 0 0 F a x : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 1 1
Page no. 31 | Configuration Interface
6.8
User Set Control
Eight user sets are available for saving different camera parameter configurations. In addition, a “Default” UserSet
is available so it will be possible to revert back to default factory settings.
Figure 21 – UserSet Control parameter configuration in GenICam Browser
6.8.1
User Set Control XML Parameters
The User Set Control parameters are summarized in Tables 14 and 15:
Parameter
Description
Gen<i>Cam name
Type
Possible values
Remarks
Value
Gen<i>Cam name
Gen<i>Cam Category: UserSetControl
User Set
Selector
Selects the feature User Set to
load, save or configure
UserSetSelector
Enumeration
(Selector)
Load User
Configuration
Loads the User Set specified
by UserSetSelector to the
device and makes it active
UserSetLoad
[UserSetSelector]
Command
1 - Activate
Save User
Configuration
Save the User Set specified by
UserSetSelector to the non-
volatile memory of the device
UserSetSave
[UserSetSelector]
Command
1 - Activate
User Set Default
Selector
Selects the feature User Set to
load and make active when
the device is reset
UserSetDefault
Enumeration
Table 16 – User Set Control parameters
Value
Gen<i>Cam name
0
Default
1
UserSet1
2
UserSet2
3
UserSet3
4
UserSet4
5
UserSet5
6
UserSet6
7
UserSet7
8
UserSet8
Table 17 – User Set Selector parameters