2-4
12V 8A DC Outlet
The 12V 8A DC Outlet is for provided
for battery charging. Follow instructions
in the owner’s manual for the battery
for charging procedures.
8A DC Circuit Breaker
The 8A DC Circuit Breaker turns off
automatically if the current exceeds 8A. If the circuit breaker turns
“OFF”
you
will need to push it “in” to turn it
“ON”
again.
Fuel Tap
The Fuel Tap controls the flow of gasoline from
the fuel tank to the carburettor. The Tap knob
should be in the
“ON”
position when starting and
operating the generator. The Tap knob should be
in the
“OFF”
position when the engine is not
running and when storing or transporting the unit.
Note:
The Fuel Tap knob helps to prevent stale fuel from remaining
in the carburettor while storing or transporting the unit. Run the
fuel out by turning the knob to the “OFF” position and letting
the engine run until it stops.
Choke
The Choke is used when starting the
engine “cold” (the
engine is not hot). Pull out fully on the choke when
starting the engine. Once the engine has warmed and a
steady idle is achieved, push in on the choke. NOTE:
When restarting a warm engine the choke is not
necessary.