Contents
1 User instructions ........................................................................................................................................ 2
1.1
User guide ....................................................................................................................................... 2
1.1.1 Abbreviations ...................................................................................................................... 2
1.1.2 Symbols .............................................................................................................................. 2
1.1.3 Target group ....................................................................................................................... 2
2 Setup methods according to DIN EN ISO 17664 ...................................................................................... 3
2.1
References ...................................................................................................................................... 3
2.2
General instructions for the reprocessing of KaVo treatment units ................................................. 4
2.2.1 Reprocessing overview Primus
®
1058 S/TM/C .................................................................. 5
2.3
Reprocessing of the surfaces of treatment unit / upholstery ........................................................... 6
2.4
Preparation of the dentist unit ......................................................................................................... 8
2.4.1 Reprocessing of holder pad/anti-slip mat ........................................................................... 8
2.4.2 Reprocessing of handle ...................................................................................................... 8
2.4.3 Reprocessing of the instrument holder (TM table / cart) .................................................. 10
2.4.4 Setting up the triple-function and multifunctional handpiece ............................................ 11
2.4.5 Preparation of the instrument hoses ................................................................................ 14
2.4.6 Servicing the turbine return air filter ................................................................................. 15
2.4.7 Reprocessing of the kit for physiological saline solution (optional) .................................. 15
2.5
Reprocessing of the assistant unit ................................................................................................ 16
2.5.1 Cleaning and disinfection of assistant element ................................................................ 16
2.5.2 Sterilisation assistant element .......................................................................................... 17
2.5.3 Preparing the connector for the suction hose ................................................................... 17
2.5.4 Reprocessing of sieve inserts and suction hoses ............................................................ 18
2.6
Preparation of the patient unit ....................................................................................................... 18
2.6.1 Preparation of the tumbler ................................................................................................ 18
2.6.2 Preparation of the tumbler holder and filler ...................................................................... 19
2.6.3 Preparation of the spittoon ............................................................................................... 20
2.7
Manual reprocessing of the water-conducting system .................................................................. 21
2.8
Automatic hygiene function of the water-conducting system ....................................................... 22
2.8.1 Rinsing program ............................................................................................................... 22
2.8.2 Intensive germ reduction (optional) .................................................................................. 26
2.9
Reprocessing and automatic hygiene functions of the suction system ......................................... 29
2.9.1 Reprocessing the suction system including suction hoses .............................................. 29
2.9.2 HYDROclean function ...................................................................................................... 30
2.10 Preparation of the amalgam separator .......................................................................................... 30
3 Replenish and check the disinfectant ...................................................................................................... 31
3.1
Replenish OXYGENAL 6 ............................................................................................................... 31
3.1.1 Replenish OXYGENAL 6 when using the water bottle ..................................................... 32
3.2
Check the OXYGENAL 6 concentration ........................................................................................ 35
Care instructions KaVo Primus® 1058 S/TM/C
Contents
1/35
Содержание Primus 1058 S
Страница 1: ...Care instructions KaVo Primus 1058 S TM C Always be on the safe side...
Страница 38: ......
Страница 39: ...1 001 6796 Fk 20131125 15 en...