Care instructions KaVo ARCTICA Engine
2 Servicing, daily | 2.1 Cleaning the housing and workspace

6 / 24

2 Servicing, daily

Note

During all servicing and cleaning work in the workspace, the air purge system (la‐

ser-spindle) must be switched on
 

Daily servicing is indicated briefly by a coloured symbol on the ARCTICA desktop.

Note

Open the protective door, press the cleaning button and select "Switch on" for the

compressed air for cleaning
See general note 1.3

2.1 Cleaning the housing and workspace

▶ Vacuum the interior of the machine daily or clean it with a paintbrush.

▶ Wipe down the outer housing and protective door with a dry, lint-free cloth.

▶ If needed, remove soiling on the outer housing and on the outside of the protec‐

tive door with a wet cloth and warm clear water, soapy water or KaVo plastics

cleaner (0.611.0030).

▶ If needed, remove soiling on the inside of the protective door with a wet cloth and

warm clear water or KaVo plastics cleaner (0.611.0030).

2.2 Emptying and cleaning the chip tray

▶ Remove the chip tray from the workspace and empty it.

▶ Take out the filter holder ② and chip sieve filter ③ from the chip tray ④.

 

 

 

 

Содержание ARCTICA

Страница 1: ...Care instructions KaVo ARCTICA Engine Always be on the safe side...

Страница 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 0 7351 56 0 Fax 49 0 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Страница 3: ...ter of the coolant lubricant container and replacing it if needed 9 3 4 Replacing the coolant lubricant 10 3 5 Cleaning the aerosol dust extractor filter and replacing it if needed 12 3 6 Checking and...

Страница 4: ...nical manufacturing background Ensure that your personnel has read these instructions for use especially the chapter Safety and understood everything Provide your personnel with the necessary personal...

Страница 5: ...cleaning work in the workspace the cleaning button must be pressed and the compressed air for cleaning must be switched on Open the protective door press the cleaning button and select Switch on for...

Страница 6: ...Cleaning the housing and workspace Vacuum the interior of the machine daily or clean it with a paintbrush Wipe down the outer housing and protective door with a dry lint free cloth If needed remove s...

Страница 7: ...ZS and ZST Blank workspace 2 3 Checking the coolant lubricant filling level Check the coolant lubricant filling level and replenish the coolant lubricant if nee ded 2 4 Checking the coolant lubricant...

Страница 8: ...Replace the coolant lubricant if the values deviate from the following recommen ded values pH value 9 0 lower by 0 5 elevated nitrite load 20mg l Water hardness values of more than 21 dH or less than...

Страница 9: ...9 9667 closure stopper Deposits can be removed by shaking in hot water Note Spent coolant lubricant and materials contaminated with coolant lubricant must be disposed of in accordance with the safety...

Страница 10: ...coolant lubricant 10 24 Re insert the coolant container in the machine 3 4 Replacing the coolant lubricant Clean the coolant container before you replace the coolant lubricant See also 2 3 2 Clean the...

Страница 11: ...ainer Fill the spent coolant lubricant into a suitable container and dispose of it according to the instructions in the safety data sheet Note Spent coolant lubricant and materials contaminated with c...

Страница 12: ...to the catch Close the tool drawer Note The coolant lubricant pump must be vented if it fails to start up after replacement of the coolant lubricant See also 2 Also refer to IfU Arctica item 7 7 Venti...

Страница 13: ...ean the clamping surfaces of the tools and block holder especially after ZS pro cessing using brass cleaning brush 1 011 4797 If there are any conspicuous coatings check the coolant lubricant for cont...

Страница 14: ...s the cleaning button and switch off the compressed air for cleaning 3 11 Checking the filter controller compressed air and drain 1 2 3 4 5 Control knob for compressed air Compressed air gauge Condens...

Страница 15: ...achine Avoid tensioning the chuck and make sure that there is always a tool in the chuck when the machine is current less or switched off Use only tools that have been released by KaVo Never insert to...

Страница 16: ...chuck NOTICE Inappropriate cleaning of the spindle and chuck Damage to the spindle and chuck Never use ultrasound steam cleaner or compressed air for cleaning Make sure that no cleaning agents get int...

Страница 17: ...chuck Insert the chuck in the spindle Slide the chuck assembly aid into the chuck until it hits the bur stop Tighten the chuck by hand until the chuck assembly aid is slightly tensioned Keep the chuc...

Страница 18: ...utton The slotted pin tension spring will be retrieved automatically 4 2 Cleaning the tool magazine holder Note Open the protective door press the cleaning button and select Switch on for the compress...

Страница 19: ...eaning brush 4 3 Replacing the coolant lubricant and cleaning the coolant tank For description refer to See also 2 3 2 Cleaning the coolant container Page 9 See also 2 3 3 Cleaning and replacing the f...

Страница 20: ...20 24 5 Servicing semi annual or according to need Semi annual servicing is indicated by a coloured symbol on the ARCTICA desktop and the ARCTICA display Clean the filter of the electronics box and r...

Страница 21: ...4 4 Finalising the cleaning work 6 Servicing annual Annual servicing is indicated by a coloured symbol on the ARCTICA desktop and the ARCTICA display Note The annual servicing of the Arctica engine m...

Страница 22: ...Care instructions KaVo ARCTICA Engine 6 Servicing annual 4 4 Finalising the cleaning work 22 24...

Страница 23: ......

Страница 24: ...1 011 5036 s 20150708 1 en...

Отзывы: