94 of 122
Operating the Reader Using the ReaderStart Software
<!--Get EPCs, CommandID: 0x0101-->
<Action>
<Description>Get EPCs</Description>
<CommandID>0101</CommandID>
<!--LSB first-->
</Action>
</ActionlistActions>
The example above shows the
Activate buzzer 500 ms
and
Get EPCs
actions.
14.7
Expert Settings 1
The ReaderStart software is a powerful tool for the reader configuration. It allows the reader to be customised to any
application. The
Expert settings 1
and
2
allow the reader's RF interface and communications profile to be optimised to the
tag so that the reader is optimally customised to the application.
There are eight parameter sets available for saving the reader configuration. It is possible to save all settings for the
transmission power, the antenna multiplex configuration, the RF settings and the air interface parameters.
Other parameters can be changed in
Expert settings 2
.
Ź
For more information about the individual parameters, refer to
Reader Configuration Manual for Kathrein RFID UHF Readers
.
2
3
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Fig. 56: Expert settings 1
Parameter Set
selects a parameter set
ཱ
Get
reads the current settings of the selected parameter set in the system
ི
Set
sets the parameters
ཱི
Enabled
activates/deactivates the possibility to make changes in the port
ུ
Power
changes the power on the port (ERP)
ཱུ
dBm/W
switches between
dBm
and
W
ྲྀ
Port power
shows the selected power on the port
ཷ
Cable
attenuation
selects cable attenuation in the range between 0 and 63.75 dB
Содержание ARU 3 Series
Страница 121: ...121 of 122...