112 of 122
Operating the Reader Using the ReaderStart Software
14.12
TagScan
To represent the relationship between the tag phase and the RSSI value, it is possible to plot both values by means of
the TagScan.
✔ There is only one tag in the field or a tag has been selected.
Ź
Click
Start
to activate the TagScan.
ᇜ
The phase shifts are seen in the frequency switching. The RSSI value does not change because the transponder
(tag) is not moved.
2
3
1
4
5
6
7
8
9
10
11
Fig. 77: TagScan: phase shift (due to the channel change), transponder is not moved
Tags
shows the number of the tags present in the antenna field
ཱ
Refresh
scans tags in the antenna field anew
ི
Start
starts TagScan
ཱི
Stop
stops TagScan
ུ
RSSI
activates/deactivates the presentation of the RSSI value in the graph
ཱུ
Phase
activates/deactivates the presentation of the phase in the graph
ྲྀ
shows the phase in form of the rotating arrow
ཷ
shows the current value of the phase
ླྀ
shows the current RSSI value
ཹ
Refresh rate
sets the interval between the commands
ེ
Number of data
points
sets the number of data points in the graph
Tip
Ź
To eliminate the phase shifts, select only one transmission frequency under
Expert settings 1
; see
Expert Set-
tings 1, p. 94
.
Содержание ARU 3 Series
Страница 121: ...121 of 122...