Important Safety & Additional Notes 

 

 

 

 

 

pg 2-3 

Tools and Supplies Needed, Unit Specs  

 

 

 

 

pg 3 

Parts Included 

 

 

 

 

 

 

 

 

pg 4 

Assembly Instructions 

 

 

 

 

 

 

 

pg 5 

 9 

Installation Instructions   

 

 

 

 

 

 

pg 10 

3-Phase Startup Procedure 

 

 

 

 

 

 

pg 11 

Maintenance  

 

 

 

 

 

 

 

 

pg 12 

Warranty 

 

 

 

 

 

 

 

 

 

pg 13 

Repair  

 

 

 

 

 

 

 

 

 

pg 14 

Troubleshooting Tips 

 

 

 

 

 

 

 

pg 15 - 16 

Replacement Parts  

 

 

 

 

 

 

 

pg 17 

Repair Contact Form 

 

 

 

 

 

 

 

pg 19 

 

Important Safety: 

Please read and follow these important instructions to help ensure your safety and the quality performance of your Kasco 
equipment. 

 

Caution should be used when dealing with any electrical and/or moving equipment. 

 

Under NO CIRCUMSTANCE should anyone enter the water with the electrical equipment plugged in and/or in 
operation.

  

 

Kasco Aerating Fountains are intended for use with a Listed control panel having a GFCI protected receptacle, or 
field wiring terminals and disconnect switch, or a timer with a disconnect for use with a GFCI receptacle. Control 
panels MUST be installed by a qualified electrician. Ground Fault Circuit Interrupters (GFCIs) should be tested upon 
each installation and every month thereafter to ensure proper operation. 

 

Single-phase aerators are supplied with an internal grounding conductor and/or a grounding-type attachment plug. 
To reduce the risk of electrical shock, be certain the aerator is properly connected to the Kasco-supplied control 
panel (refer to the instructions included with your C-85 or C-95 Control Panel). 

 

3-phase aerators (2.3VFX, 5.3VFX, 2.3HVFX, 5.3HVFX) require a startup test after wiring to ensure proper rotation 
of the propeller. If the propeller is rotating in the opposite direction, the unit will not perform properly and internal 
damage to the unit may occur (see 3-phase startup procedure on page 11). 

 

NEVER run the unit out of the water. This will damage the seals and create a dangerous situation for the operator. 

 

Extreme caution should be used around water, especially cold water, as in Spring, Fall, and Winter, which poses a 
hazard in and of itself.  

Содержание VFX Series

Страница 1: ...1 Manual Number 884172 Owners Manual VFX Series Aerators 8400VFX 5 1VFX 2 3VFX 5 3VFX 2 3HVFX 5 3HVFX Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 kascomarine com Rev 5 2020...

Страница 2: ...r use with a GFCI receptacle Control panels MUST be installed by a qualified electrician Ground Fault Circuit Interrupters GFCIs should be tested upon each installation and every month thereafter to e...

Страница 3: ...arrier that will make the unit inaccessible to persons in the water A complete list of control panels can be found in the Accessories section of kascomarine com Additional Notes During flotation opera...

Страница 4: ...4 Unit Size H PartNo D PartNo 2hp 8400VFX 284102 2hp 3 phase 2 3VFX 284103 5hp 5 1VFX 284105 5hp 3 phase 5 3VFX 284105 Parts Included...

Страница 5: ...wrench Repeat for all three legs on the unit assembly Step 2 Place the float D over the unit assembly so that it rests on the L brackets Ensure the three channels on the inside of the float line up wi...

Страница 6: ...n C to the ledge on the top of the float using the 3 8 16 x 3 hex head screw A and 3 8 lock washer B through the hole in the L bracket using the 9 16 socket wrench Repeat for all three upper screen se...

Страница 7: ...the mesh screen L and wrap into a cone shape by overlapping both vertical edges by approximately 1 inch and aligning top and bottom edges of mesh as shown Secure mesh vertical seam at the top bottom...

Страница 8: ...the float allowing the unit power cord to exit between them in the dedicated channel Dedicated power cord channel Step 7 Flip mesh and screen assembly over and use remaining cable ties to secure mesh...

Страница 9: ...is between the two flanges on each clip as shown Tighten all three serrated hex head screws to secure the screen to the bottom of the float being sure not to pinch the power cord 9 16 socket or combin...

Страница 10: ...ignificantly a small weight may need to be suspended at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized pipe works well The weight should be light...

Страница 11: ...lectrician 1 Verify all screw terminal connections are tightened to specified torque setting prior to energizing the panel 2 Verify the electrical service voltage and phase matches the control panel a...

Страница 12: ...od of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEANING Aerators should be removed from the water...

Страница 13: ...CONSEQUENTIAL DAMAGES Warranty is void if The aerator is not maintained properly according to the Maintenance Recommendations supplied in this Owner s Manual The aerator is returned for repair withou...

Страница 14: ...uthorized Repair Center or to Kasco at Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Attn Repairs Non Warranty Repairs Most failed equipment can be repaired at substantially lower costs than replace...

Страница 15: ...but not spinning and can be started by spinning the prop with a stick the Starting capacitor needs to be replaced by an Authorized Repair Center My Aerator turns itself off and back on without the tim...

Страница 16: ...is placed It is caused by either induced current in the ground wire or a base voltage difference due to soil pH levels To resolve the problem contact an electrician and install a local grounding stake...

Страница 17: ...17 Replacement Parts Unit Size H PartNo D PartNo 2hp 8400VX 284102 2hp 3 phase 2 3VX 284103 5hp 5 1VX 284105 5hp 3 phase 5 3VX 284105...

Страница 18: ...18...

Страница 19: ...unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshooting rule ou...