NEVER lift or drag the equipment by the power cords. If you need to pull the unit to the side of the pond, use the 
anchoring ropes.  

 

Do not use boats that tip easily for installation and follow all boating safety rules and regulations, including wearing a 
PFD (Personal Flotation Device). Do not use waders in deep ponds/lakes or ponds/lakes with drop-offs, drastic 
slopes, or soft bottom material. 

 

For more information regarding your control panel instructions, refer to your control panel 

owner’s manual

. A control 

panel must be installed a minimum of 5 feet (3m in Canada) from the body of water unless separated from the body 
of water by a fence, wall, or other permanent barrier that will make the unit inaccessible to persons in the water. A 
complete list of control panels can be found in the Accessories section of kascomarine.com. 

Additional Notes 

During flotation operation, water is pulled from 360° around and directly below the unit. Keep these areas clear of debris as 

much as possible to decrease frequency of screen cleaning. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tools and Supplies Needed 

 

(3) Anchors or stakes for installing unit  

 

208/240VAC single-phase or 240VAC or 460VAC 3-phase electrical supply near pond on a post with room for 
mounting the supplied control panel 

 

(4) 

#10 x 1’’ 

long or longer screws for mounting the supplied control panel 

 

9/16

’’ socket with extension

 and ratchet 

 

7/16

’’ socket 

and ratchet or combination wrench  

 

(3) 

12’’ pieces of 1’’ galvanized pipe for weighting ropes (optional)

 

9/16

’’ socket 

(extension not shown) 

7/16

’’

combination wrench 

Unit Specs & Pattern Size 

Содержание VFX Series

Страница 1: ...1 Manual Number 884172 Owners Manual VFX Series Aerators 8400VFX 5 1VFX 2 3VFX 5 3VFX 2 3HVFX 5 3HVFX Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 kascomarine com Rev 5 2020...

Страница 2: ...r use with a GFCI receptacle Control panels MUST be installed by a qualified electrician Ground Fault Circuit Interrupters GFCIs should be tested upon each installation and every month thereafter to e...

Страница 3: ...arrier that will make the unit inaccessible to persons in the water A complete list of control panels can be found in the Accessories section of kascomarine com Additional Notes During flotation opera...

Страница 4: ...4 Unit Size H PartNo D PartNo 2hp 8400VFX 284102 2hp 3 phase 2 3VFX 284103 5hp 5 1VFX 284105 5hp 3 phase 5 3VFX 284105 Parts Included...

Страница 5: ...wrench Repeat for all three legs on the unit assembly Step 2 Place the float D over the unit assembly so that it rests on the L brackets Ensure the three channels on the inside of the float line up wi...

Страница 6: ...n C to the ledge on the top of the float using the 3 8 16 x 3 hex head screw A and 3 8 lock washer B through the hole in the L bracket using the 9 16 socket wrench Repeat for all three upper screen se...

Страница 7: ...the mesh screen L and wrap into a cone shape by overlapping both vertical edges by approximately 1 inch and aligning top and bottom edges of mesh as shown Secure mesh vertical seam at the top bottom...

Страница 8: ...the float allowing the unit power cord to exit between them in the dedicated channel Dedicated power cord channel Step 7 Flip mesh and screen assembly over and use remaining cable ties to secure mesh...

Страница 9: ...is between the two flanges on each clip as shown Tighten all three serrated hex head screws to secure the screen to the bottom of the float being sure not to pinch the power cord 9 16 socket or combin...

Страница 10: ...ignificantly a small weight may need to be suspended at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized pipe works well The weight should be light...

Страница 11: ...lectrician 1 Verify all screw terminal connections are tightened to specified torque setting prior to energizing the panel 2 Verify the electrical service voltage and phase matches the control panel a...

Страница 12: ...od of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEANING Aerators should be removed from the water...

Страница 13: ...CONSEQUENTIAL DAMAGES Warranty is void if The aerator is not maintained properly according to the Maintenance Recommendations supplied in this Owner s Manual The aerator is returned for repair withou...

Страница 14: ...uthorized Repair Center or to Kasco at Kasco Marine Inc 800 Deere Rd Prescott WI 54021 Attn Repairs Non Warranty Repairs Most failed equipment can be repaired at substantially lower costs than replace...

Страница 15: ...but not spinning and can be started by spinning the prop with a stick the Starting capacitor needs to be replaced by an Authorized Repair Center My Aerator turns itself off and back on without the tim...

Страница 16: ...is placed It is caused by either induced current in the ground wire or a base voltage difference due to soil pH levels To resolve the problem contact an electrician and install a local grounding stake...

Страница 17: ...17 Replacement Parts Unit Size H PartNo D PartNo 2hp 8400VX 284102 2hp 3 phase 2 3VX 284103 5hp 5 1VX 284105 5hp 3 phase 5 3VX 284105...

Страница 18: ...18...

Страница 19: ...unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshooting rule ou...