2 – 3 HP J SERIES FOUNTAIN
MANUAL
884168 / 2021.1.1
3
TOOLS AND SUPPLIES NEEDED
• (3) Anchors or stakes for installing unit
• 208-240V electrical supply near pond on a post with room for mounting the control panel
• (4) #10 x 1’’ long or longer screws for mounting the control panel
• 9/16’’ socket with extension and ratchet (optional)
• 7/16’’ socket and ratchet or combination wrench (optional)
• (3) 12’’ pieces of 1’’ galvanized pipe for weighting ropes (optional)
Model
HP
Voltage
Operating Amps Locked-Rotor Amps Control Panel Connection
Unit Connection
Single-Phase Units
8400JF
2
208-240
10
40
Hardwire C-85
Hardwire C-85
3.1JF
3
208-240
13�4
61
Hardwire C-95
Hardwire C-95
5.1JF
5
208-240
20
97
Hardwire C-95
Hardwire C-95
3-Phase Units
2.3JF
2
208
7�5
40
See control panel instructions
3.3JF
3
208
10�3
70
5.3JF
5
208
16
100
7.3JF
7�5
208
20
100
2.3HJF
2
460
3�8
24
3.3HJF
3
460
5�2
40
5.3HJF
5
460
8
49
7.3HJF
7�5
460
10
50
installed a minimum of 5 feet (3m in Canada) from the body of water unless separated from the body of water by a fence, wall, or
other permanent barrier that will make the unit inaccessible to persons in the water� A complete list of control panels can be found
section of kascomarine�com�
Additional Notes
During flotation operation, water is pulled from 360° around and directly below the unit. Keep these areas clear of debris as much as
possible to decrease frequency of screen cleaning�
UNIT SPECS
Back to Contents