MAINTENANCE RECOMMENDATIONS

Under 

NO CIRCUMSTANCES

 should anyone enter the water while a fountain is operating�

The following maintenance procedures can be utilized to ensure many years of quality performance from your Kasco equipment and 

reduce the need for more costly repair work�

PROPER INSTALLATION:

  Proper installation of Kasco equipment will include a power source with ground fault protection� The control 

panel included with the equipment has built-in ground fault protection for both the fountain and the lighting kit� Ground fault interrupters 

are a safety feature that can also alert you to electrical leaks in the equipment� It is extremely important to test the GFI upon installation 

and every month thereafter to ensure proper operation� If you have repeat, consistent trips of the ground fault device, the equipment 

should be disconnected and removed from the water� The power cord should be inspected for damage� and you should contact your 

distributor or contact Kasco Marine at 715-262-4488 or sales@kascomarine�com for further instructions� A complete list of control pan-

els can be found in the 

Accessories

 section of kascomarine�com�

OBSERVATION:

 Operating equipment should be observed on a regular basis (daily, if possible) for any reduction or variation in perfor-

mance� If a change in performance is observed, the equipment should be disconnected from power and inspected� 

WINTER STORAGE:

 In regions where there is significant freezing in the wintertime, the equipment should be removed from the water 

to protect it from the expansion pressure of ice� The unit may keep some amount of ice open, but when water is thrust into the air, it can 

make the existing ice thicker. Storage over winter is best in a location that is out of the sun and cool, but above 32° F. Store unit upside 

down if it will sit for a long period of time to ensure continued oil lubrication of seals; units that sit upright for many months or years have 

a greater likelihood of seals drying out�

CLEANING: 

Equipment should be removed from the water at least once per year (at the end of the season in cold climates) to clean 

the exterior of the system, especially the stainless-steel motor housing (can) that dissipates heat into the water� Any algae, calcium, or 

other build-up will become an insulator that blocks heat transfer and may lead to overheating and damage� In warmer regions, the unit 

should be removed and cleaned at least 2 – 3 times per year. In most cases, a power washer is sufficient if the unit and algae are still 

wet�

SEAL AND OIL REPLACEMENT:

 This is a sealed motor assembly, and seals will wear out over time (similar to brake pads on a car)� 

Replacement of the seals and a change of oil after three years may add longevity to the operation of the motor, saving you the cost of 

more expensive repairs� In warmer climates where the fountain runs for a majority of the year or greater, it is wise to replace seals more 

often�

ZINC ANODE:

 A sacrificial zinc anode is supplied on the shaft of all motor units for protection from corrosion and electrolysis. The zinc 

anode should be updated/replaced if reduced to half the original size or if white in color� Corrosion from electrolysis is more commonly 

associated with saltwater or brackish water, but as a matter of precaution, it is important to periodically check the zinc anode in all 

installations (at least every two to three months)� 

Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco-trained Authorized Repair Center� Any 

alterations or changes made to Kasco units by an unauthorized source will void the warranty� This includes tampering with the unit, 

power cord, and/or control panel� Contact Kasco Marine at 715-262-4488 or sales@kascomarine�com for additional information and 

your closest Authorized Repair Center�

Back to Contents

Содержание J Series

Страница 1: ...J Series Fountain 8400JF 3 1JF 2 3JF 3 3JF 2 3HJF 3 3HJF Operation Maintenance Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 884168...

Страница 2: ...st after wiring to ensure proper rotation of the impeller If the impeller is rotating in the opposite direction the unit will not perform properly and internal damage to the unit may occur see 3 phase...

Страница 3: ...61 Hardwire C 95 Hardwire C 95 5 1JF 5 208 240 20 97 Hardwire C 95 Hardwire C 95 3 Phase Units 2 3JF 2 208 7 5 40 See control panel instructions 3 3JF 3 208 10 3 70 5 3JF 5 208 16 100 7 3JF 7 5 208 20...

Страница 4: ...O ring Large J 1 841217 G Large JF unit assembly 1 See Table below H Bottom screen Large J 1 284101 I 3 8 16 x 1 2 serrated hex head screw 3 820092 J 7 16 9 16 wrench tool 1 284139 K Rope 50ft not pic...

Страница 5: ...284302 3 19 34 5 18 34 284305 7 5 21 36 4 Linden Center geyser with lower conical pattern uses Outlet nozzle 2 15 5 38 284302 3 20 5 38 5 24 5 46 284305 7 5 26 46 5 Redwood Tall and narrow geyser use...

Страница 6: ...our local distributor for order information Mighty Oak Mahogany Palm Magnolia Fig 4 Pattern Description HP Height Width Part Palm 1 tier of 12 arcing streams 2 12 26 841320 3 16 36 5 20 5 40 7 5 22 42...

Страница 7: ...lines up with the power cord on the unit assembly This will allow the power cord to run in the power cord channel on the underside of the float later 2 Using the 9 16 side of the wrench tool J or a so...

Страница 8: ...x 1 2 serrated hex head screws I but do not tighten down at this time 4 Lift the unit and slide the bottom float screen H over the can and up to the bottom of the float allowing the unit power cord t...

Страница 9: ...rain relief as shown below Unit is ready for installation into the pond Any lights or other optional equipment installation including nozzle selection should be made at this time Refer to instructions...

Страница 10: ...are completely snug Nozzles can be changed conveniently without removing the float or using any tools Note If it is difficult to twist the nozzle into place dielectric grease M can be applied to the...

Страница 11: ...ded at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized pipe works well The weight should be light enough so that the fountain can rise as the water...

Страница 12: ...sco 3 phase panel is supplied follow the instructions included with the panel in addition to the steps below Electrician 1 Verify all screw terminal connections are tightened to specified torque setti...

Страница 13: ...nit upside down if it will sit for a long period of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEA...

Страница 14: ...eipt and registering the equipment online at kascomarine com under the Warranty Information section Once warranty coverage has been established the unit may be sent to Kasco Marine or any Kasco Author...

Страница 15: ...k is performed All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer Rejected equipment can be returned at the customer s expense for shipping and hand...

Страница 16: ...needs to be replaced by an Authorized Repair Center My unit turns itself off and back on without the timer and without tripping the GFI breaker single phase units only Each Kasco fountain has a Therm...

Страница 17: ...tomer to ship and pay freight to Kasco Note Contact Information should be that of the person or company to contact for repair information Company name Contact name First name Last name Address Street...

Отзывы: