2 – 3 HP J SERIES FOUNTAIN

MANUAL

884168 / 2021.1.1

12

3-PHASE STARTUP PROCEDURE

If a Kasco Control Panel is not provided, please refer to the following warnings: 

When inherent overheating protection is not provided: use with approved motor control that matches motor input in full load amperes 

with overload element(s) selected or adjusted in accordance with control instructions� 

Utiliser un démarreur approuvé convenant au 

courant à pleine charge du moteur et dont les éléments thermiques sont réglés ou choisis conformément aux instructions qui l’accom-

pagnent. 

When inherent overheating protection is provided: use with approved motor control that matches motor input in full load amperes� See 

table below� 

Utiliser un démarreur approuvé convenant au courant à pleine charge du moteur.

Note: The motor input in full load amperes is the marked value or the service factor amperes, shown on the nameplate�

3-phase 208-230V

2.3JF

3.3JF

5.3JF

7.3JF

Full load amps

7�5

10�3

16

20

3-phase 460V

2.3HJF 3.3HJF 5.3HJF 7.3HJF

Full load amps

3�8

5�2

8

10

Control panels must be installed by a qualified electrician. 

If unit is connected to a circuit protected by a fuse, use a time-delay fuse with this pump� 

You must verify motor rotation before installing the unit in the water. 

3-phase Kasco units will run in a clockwise rotation when 

looking down at the propeller� Keep clear of the propeller while verifying rotation� Air will be blowing out (up) of the pump chamber when 

rotating in the correct direction� If a Kasco 3-phase panel is supplied, follow the instructions included with the panel in addition to the 

steps below�

Electrician: 

1� 

Verify all screw terminal connections are tightened to specified torque setting prior to energizing the panel. 

2�  Verify the electrical service (voltage and phase) matches the control panel and fountain nameplate ratings� Refer to the control 

panel instructions and schematics for installation details� 

3�  Verify all switches, circuit breakers, and motor starters are in the OFF position

4�  Connect electrical service to the control panel as shown in the electrical schematic that came with the panel� 

5�  Connect the fountain power cord to the panel as shown in the electrical schematic� 

6�  Set the motor starter overload to the FLA rating on the fountain nameplate� 

7�  Pump rotation: The pump rotation is clockwise when looking down at the propeller� Apply power to the control panel� Turn on the 

15-amp control circuit breaker and motor starter� 

8�  Momentarily turn the Hand-Off-Auto switch to Hand� This will run the fountain� Do not run the fountain for more than a few seconds 

on shore� If the rotation is not correct, disconnect and lock out power from the control panel� Swap any two of the fountain power 

cord wires in the panel� This will cause the motor to reverse direction� Reapply power to the panel and verify the rotation is clock-

wise� 

9� 

Once rotation is verified, with the power disconnected and locked out again, continue with installation of the fountain on page 9.

L1-L2 

  Volts 

 

 L1 

  Amps

L1-L3 

  Volts 

 

 L2 

  Amps

L2-L3 

  Volts 

 L3 

  Amps

Current unbalance should not exceed 5% at full load�

Record the following data while the unit is 

operating in the water under load:

Back to Contents

Содержание J Series

Страница 1: ...J Series Fountain 8400JF 3 1JF 2 3JF 3 3JF 2 3HJF 3 3HJF Operation Maintenance Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 884168...

Страница 2: ...st after wiring to ensure proper rotation of the impeller If the impeller is rotating in the opposite direction the unit will not perform properly and internal damage to the unit may occur see 3 phase...

Страница 3: ...61 Hardwire C 95 Hardwire C 95 5 1JF 5 208 240 20 97 Hardwire C 95 Hardwire C 95 3 Phase Units 2 3JF 2 208 7 5 40 See control panel instructions 3 3JF 3 208 10 3 70 5 3JF 5 208 16 100 7 3JF 7 5 208 20...

Страница 4: ...O ring Large J 1 841217 G Large JF unit assembly 1 See Table below H Bottom screen Large J 1 284101 I 3 8 16 x 1 2 serrated hex head screw 3 820092 J 7 16 9 16 wrench tool 1 284139 K Rope 50ft not pic...

Страница 5: ...284302 3 19 34 5 18 34 284305 7 5 21 36 4 Linden Center geyser with lower conical pattern uses Outlet nozzle 2 15 5 38 284302 3 20 5 38 5 24 5 46 284305 7 5 26 46 5 Redwood Tall and narrow geyser use...

Страница 6: ...our local distributor for order information Mighty Oak Mahogany Palm Magnolia Fig 4 Pattern Description HP Height Width Part Palm 1 tier of 12 arcing streams 2 12 26 841320 3 16 36 5 20 5 40 7 5 22 42...

Страница 7: ...lines up with the power cord on the unit assembly This will allow the power cord to run in the power cord channel on the underside of the float later 2 Using the 9 16 side of the wrench tool J or a so...

Страница 8: ...x 1 2 serrated hex head screws I but do not tighten down at this time 4 Lift the unit and slide the bottom float screen H over the can and up to the bottom of the float allowing the unit power cord t...

Страница 9: ...rain relief as shown below Unit is ready for installation into the pond Any lights or other optional equipment installation including nozzle selection should be made at this time Refer to instructions...

Страница 10: ...are completely snug Nozzles can be changed conveniently without removing the float or using any tools Note If it is difficult to twist the nozzle into place dielectric grease M can be applied to the...

Страница 11: ...ded at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized pipe works well The weight should be light enough so that the fountain can rise as the water...

Страница 12: ...sco 3 phase panel is supplied follow the instructions included with the panel in addition to the steps below Electrician 1 Verify all screw terminal connections are tightened to specified torque setti...

Страница 13: ...nit upside down if it will sit for a long period of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEA...

Страница 14: ...eipt and registering the equipment online at kascomarine com under the Warranty Information section Once warranty coverage has been established the unit may be sent to Kasco Marine or any Kasco Author...

Страница 15: ...k is performed All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer Rejected equipment can be returned at the customer s expense for shipping and hand...

Страница 16: ...needs to be replaced by an Authorized Repair Center My unit turns itself off and back on without the timer and without tripping the GFI breaker single phase units only Each Kasco fountain has a Therm...

Страница 17: ...tomer to ship and pay freight to Kasco Note Contact Information should be that of the person or company to contact for repair information Company name Contact name First name Last name Address Street...

Отзывы: