background image

J Series Fountain

8400JF, 3.1JF, 2.3JF, 3.3JF, 2.3HJF, 3.3HJF

Operation & Maintenance Manual

800 Deere Rd. Prescott, WI 54021  •  715.262.4488  •   [email protected]  •   www.kascomarine.com

Document number 884168

Содержание J Series

Страница 1: ...J Series Fountain 8400JF 3 1JF 2 3JF 3 3JF 2 3HJF 3 3HJF Operation Maintenance Manual 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com www kascomarine com Document number 884168...

Страница 2: ...st after wiring to ensure proper rotation of the impeller If the impeller is rotating in the opposite direction the unit will not perform properly and internal damage to the unit may occur see 3 phase...

Страница 3: ...61 Hardwire C 95 Hardwire C 95 5 1JF 5 208 240 20 97 Hardwire C 95 Hardwire C 95 3 Phase Units 2 3JF 2 208 7 5 40 See control panel instructions 3 3JF 3 208 10 3 70 5 3JF 5 208 16 100 7 3JF 7 5 208 20...

Страница 4: ...O ring Large J 1 841217 G Large JF unit assembly 1 See Table below H Bottom screen Large J 1 284101 I 3 8 16 x 1 2 serrated hex head screw 3 820092 J 7 16 9 16 wrench tool 1 284139 K Rope 50ft not pic...

Страница 5: ...284302 3 19 34 5 18 34 284305 7 5 21 36 4 Linden Center geyser with lower conical pattern uses Outlet nozzle 2 15 5 38 284302 3 20 5 38 5 24 5 46 284305 7 5 26 46 5 Redwood Tall and narrow geyser use...

Страница 6: ...our local distributor for order information Mighty Oak Mahogany Palm Magnolia Fig 4 Pattern Description HP Height Width Part Palm 1 tier of 12 arcing streams 2 12 26 841320 3 16 36 5 20 5 40 7 5 22 42...

Страница 7: ...lines up with the power cord on the unit assembly This will allow the power cord to run in the power cord channel on the underside of the float later 2 Using the 9 16 side of the wrench tool J or a so...

Страница 8: ...x 1 2 serrated hex head screws I but do not tighten down at this time 4 Lift the unit and slide the bottom float screen H over the can and up to the bottom of the float allowing the unit power cord t...

Страница 9: ...rain relief as shown below Unit is ready for installation into the pond Any lights or other optional equipment installation including nozzle selection should be made at this time Refer to instructions...

Страница 10: ...are completely snug Nozzles can be changed conveniently without removing the float or using any tools Note If it is difficult to twist the nozzle into place dielectric grease M can be applied to the...

Страница 11: ...ded at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized pipe works well The weight should be light enough so that the fountain can rise as the water...

Страница 12: ...sco 3 phase panel is supplied follow the instructions included with the panel in addition to the steps below Electrician 1 Verify all screw terminal connections are tightened to specified torque setti...

Страница 13: ...nit upside down if it will sit for a long period of time to ensure continued oil lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEA...

Страница 14: ...eipt and registering the equipment online at kascomarine com under the Warranty Information section Once warranty coverage has been established the unit may be sent to Kasco Marine or any Kasco Author...

Страница 15: ...k is performed All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer Rejected equipment can be returned at the customer s expense for shipping and hand...

Страница 16: ...needs to be replaced by an Authorized Repair Center My unit turns itself off and back on without the timer and without tripping the GFI breaker single phase units only Each Kasco fountain has a Therm...

Страница 17: ...tomer to ship and pay freight to Kasco Note Contact Information should be that of the person or company to contact for repair information Company name Contact name First name Last name Address Street...