manualshive.com logo in svg
background image

HYDRA

FORCE

HYDRAFORCE LIFT STATION AGITATOR MANUAL

18

REPAIR CONTACT FORM

Company name

Contact name

First name

Last name

Address

Street

City

State

ZIP code

Phone number

Primary

Alternate

Email address
Preferred method of 

contact (circle one)

              Phone                          Email

Purchase order 

number

Additional product 

information

Serial Number

Cord Length

Information for Repair Technician

Was this unit used in a chemical treatment or wastewater 

application? (circle one)

                   Yes                              No

Additional notes

Kasco Marine

800 Deere Road

Prescott, WI 54021

Attn: Repairs

•  Kasco requires that all equipment sent for repair MUST be 

accompanied by this form and marked to Repairs attention.

•  Unit should be cleaned before shipping.

•  Kasco is NOT responsible for shipping damage accrued in 

return shipment.

•  It is the responsibility of the customer to ship and pay freight 

to Kasco.

Note: Contact information should be that of the person or company to contact for repair information. 

Back to Contents

Содержание HYDRAFORCE LS-100

Страница 1: ...AIRE MANUAL 1 800 Deere Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com Installation Operation Manual Document number 884190 Document version 2023 1 0 AGITATOR LIFT STATION HYD...

Страница 2: ...om QUESTIONS Safety First 2 Unit Specifications 2 Parts Included List 3 Parts Included Illustration 4 Post Mount Cabinet Installation 5 No Cabinet Installation 6 Hatch Chain Installation 9 Assembly In...

Страница 3: ...ETY FIRST WARNINGS Model Number Number of diffusers Voltage Phase Compressor HP Amps Number of 50 ft rolls of 3 8 tubing included LS 100 1 120V 1 1 4 2 5 1 LS 150 1 120V 1 1 2 3 5 1 LS 200 2 120V 1 1...

Страница 4: ...J SureSink tubing 50 ft 773375 1 1 2 3 K Tube fitting kit 773300 1 1 2 3 L Cable tie 415038 9 9 18 27 Diffuser Kit PN 636392 M Diffuser substrate 772030 2 2 4 6 N Diffuser substrate connector 772031 1...

Страница 5: ...HYDRAFORCE HYDRAFORCE LIFT STATION AGITATOR MANUAL 4 PARTS INCLUDED ILLUSTRATION A I H F P M N U Q O R T S D E B C G J L Back to Contents...

Страница 6: ...cabinet to the wall or post No key is required to open cabinet Simply use a flat head screwdriver 1 Drill two 3 16 holes vertically spaced 2 3 8 apart 2 Using a standard 7 16 socket wrench install bo...

Страница 7: ...d cooling air airflow across the compressor is essential to prevent damage to the compressor from overheating A fan is included for this purpose Easily mount the unit to a wall floor or bench with the...

Страница 8: ...ilter 1 Three station manifold assembly 1 Manifold mounting screw 2 LS 300 NC Parts Included Qty Diffuser Assembly 3 3 8 x 50 SureSink Tubing w fitting kit 3 Double head compressor 1 1 4 NPT x 3 8 bar...

Страница 9: ...cabinet systems arrive assembled To prepare for installation 1 Thread the filter maintenance indicator into the top port of the intake manifold block Hand tighten and DO NOT OVER TIGHTEN The fitting i...

Страница 10: ...onry drill bit drill a hole that is at least 1 deep at each end of the hatch 2 Place one concrete anchor C in each hole with the female thread facing toward the center of the hatch 3 Insert installati...

Страница 11: ...h diffuser loops P face the same direction and are parallel with the inlet check valve assembly O Using an adjustable wrench tighten the hose barb R into the inlet check valve assembly O 2 Assemble bo...

Страница 12: ...r diffuer loop P For best performance keep an equal amount of tubing on either side of substrates M P N U 5 Slide the edge guards U onto the substrate connector plate N as shown 6 Rotate the entire as...

Страница 13: ...with the six provided lock nuts S to temporarily hold them in place S T N 8 Flip the diffuser assembly back over and tighten down each lock nut S until snug with a socket wrench or a 7 16 nut driver...

Страница 14: ...ins to the loop in the cable F H I 11 12 H I N I P H 13 14 H F 15 16 Determine the length of cable F needed to submerge diffuser assembly in lift station For optimal performance the diffuser should be...

Страница 15: ...he free end of SureSink tubing J to the outlet lead hose on the compressor Secure with hose barb and hose clamps from tube fitting kit K SureSink tubing will need provisions to pass through or around...

Страница 16: ...mpressor is not Inspect the compressor and capacitor wiring and connections The compressor and fan are running but there are no bubbles coming out of any diffusers Check for leaks in line connections...

Страница 17: ...ir Form or call to locate your nearest Authorized Repair Center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your local distributor with the...

Страница 18: ...the customer If the customer would like the compressor returned we will restore the compressor as closely as possible to the condition in which we found it and ship at the customer s expense includin...

Страница 19: ...s unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for r...

Отзывы: