HYDRA
FORCE
HYDRAFORCE LIFT STATION AGITATOR MANUAL
15
WINTER OPERATION
The system owner assumes all risks of operating the HydraForce Lift Station Agitator during winter
months.
MAINTENANCE
Warning!
Product surfaces become very hot during operation. Allow compressor to cool before servicing.
Disconnect electrical power before performing maintenance.
•
Check filter monthly.
•
Clean or replace intake filter when filter minder shows a
red band.
•
Reset by pushing the small button on the minder top.
•
Failure to maintain clean air filter will lead to excessive
heat and premature failure of the compressor.
•
Replacement air filter element part number: 771018
Clean filter
Dirty filter
TROUBLESHOOTING
“Compressor and fan are not running.”
•
Ensure the power cord is connected. Check if the user supplied GFCI circuit is tripped. Reset as
necessary
“The fan is running but the compressor is not”
•
Inspect the compressor and capacitor wiring and connections.
“The compressor and fan are running, but there are no bubbles coming out of any diffusers”
•
Check for leaks in line connections and at the compressor. Check connections for tightness.
“The compressor and fan are running. There are bubbles coming out of some diffusers, but not all of them.”
•
The valves in the cabinet may need to be balanced. There may be a clogged diffuser that needs to be
cleared. The compressor may be due for a rebuild.
“The compressor stops and restarts”
•
Ensure the fan is working properly. Capacitor may need replacement.
Please contact Kasco or your distributor if any problems persist.
In climates where temperatures fall below freezing, Kasco recommends insulating the air lines from the
compressor cabinet to a minimum of 3 feet into the water (use low water level for reference). Prevent ice
buildup in the lines by using closed cell polyurethane foam to insulate. Ice buildup can block the flow of air
to your diffuser and cause damage to your compressor.