![Karmann Colorado Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/karmann/colorado/colorado_operating-instructions-manual_3518294071.webp)
Power supply
FAULT IDENTIFICATION AND ELIMINATION
12-4
Fault
Body battery does not supply any voltage
Body battery does not charge during travel
Body battery does not charge when
connected to 230 V network
(Charge indicator of 230 V network is via
green indicator lamp on control panel).
Possible cause
Body battery discharged to low level
Connector contacts and connections
defective
Fuses or relay in battery charger defective
230 V automatic circuit breaker switched off
Fuses or relay in battery charger defective
Remedy
If the battery if discharged to low level it is
irreparably damaged and must be replaced.
When the vehicle is temporarily laid up for
the winter, charge the body battery and
disconnect the terminals, pay attention to
silent consumers (e.g. frost protection valve)
Check and correct if necessary
Contact specialist repair shop
Switch on circuit breaker
Contact specialist repair shop