![Karmann Colorado Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/karmann/colorado/colorado_operating-instructions-manual_3518294040.webp)
Heating and Hot Water Supply
GAS INSTALLATION
5-3
pilot light (B) of the knob must light up. If
the light does not light up, check the fuse
III on the control panel (p. 6-2).
C = Knob with five positions
- Up = Boiler (summer mode,
temperature 60°C or 40°C)
- Middle = Off
- Down 1 = H Boiler (winter mode,
without hot water requirement)
- Down 2 = H Boiler (winter mode,
with hot water requirements, 60°C)
D = Red pilot light "Fault"
Indicates a fault in the gas or power sup
ply. In such a case consult the fault table
(see p. 12-2) or the attached operating in
structions of the combination unit.
In
winter mode
the unit determines
automatically through the thermostat which
burner stage is needed.
Once the desired temperature has been
reached:
- with the switch at
Down 1
, the heating
switches off regardless of the water
temperature, and with the boiler full the
water is automatically also heated, or
- with the switch at
Down 2
, the hot air fan of
the heating switches off and the content of
the boiler is heated up to 60°C at the lowest
burner stage.
Control element and modes of
operation
A = Knob for room temperature
When the unit is switched on the green
A
E
D
B
C
Up
Middle
Down 1
Down 2
The Trumatic heating system in your
Karmann Mobile Home is equipped in
addition with an integrated 12 ltr. Boiler to
supply the bathroom and the kitchen with hot
water. The combination unit is located under
the wardrobe (550, 600, 650, 660, 655TI, 665TI,
675TI) and under the bed (625TI). The control
element is mounted above the body door. The
warmed heating air is distributed throughout
the living room by means of a circulation fan.
In
summer mode
(water heating without room
heating) the service water is heated up on
the lowest burner stage. Once the water
temperature set has been reached, the
burner switches off. The yellow lamp (E) goes
out.