MS48IP Programming Guide
82
Call Record Media And Status:
That program defines the device to which the call records are to be output and the
type of calls to be recorded.
8 7 7 P R
Parameters
P
:
0
No recording
:
1
Only international outgoing calls are recorded.
:
2
Only long distance and international outgoing calls are recorded.
:
3
All outgoing calls on lines are recorded.
:
4
Unanswered incoming calls and all outgoing line calls are recorded.
:
5
All incoming and outgoing line calls are recorded.
R
:
0
The call records are sent to PC (Net-CM)
:
1
The call records are sent to serial printer
:
2
The call records are sent to KY16 Mini Printer
Default Value
P=3, R=0.
Call Record Counter Reset (Only for operator):
All the call records are output with a 4 digit counter number. If required this counter
can be reset to 0000.
8 7 6 9