1.4

 

Warranty 

 

Hawk products are warranted by LEUCO S.p.A. to be free of defects in materials and workmanship for a period of one (1) year starting 
from the date of their release from the factory. 
This warranty is limited to the repair and replacement of parts and products which, at the sole discretion of LEUCO S.p.A., are deemed 
defective as of the time of delivery. All products under this limited warranty shall be returned, freight prepaid, for inspection, repair or 
replacement by the manufacturer. 
The  limited  warranty  hereto  is  valid  in  place  of  any  other  warranty,  whether  express  or  implicit,  including  all  warranties  of 
merchantability or suitability for special purposes. These warranties are hereby rejected and excluded by the manufacturer. 
Repairs  or  replacements  of  defective  products  shall  be  carried  out  in  exclusive  and  sole  compliance  with  the  procedures  described 
herein, and LEUCO S.p.A. shall not be liable for any further loss, damage or charge, including accidental and indirect damage, that may 
be caused directly or indirectly by the sales or use of these products. 
Unauthorised use of spare parts that are not originally manufactured by LEUCO S.p.A. shall automatically void the warranty, which is 
governed by the instructions for installation and operation specified herein. No other warranty exists extending beyond the description 
above. 

 

 

 

All  pumps  supplied  by  LEUCO  have  been  carefully  checked  during  production  and  subjected  to  testing  
cycles  before  shipment.  To  achieve  the  best  performance  levels,  avoid  unpleasant  inconveniences,  and 
keep the warranty conditions valid, the procedures described in this manual concerning correct installation 
and priming of the pump must strictly be adhered to. 
LEUCO S.p.A. declines any and all responsibility for errors in the drafting of this manual. 

 

 

Changes to the product, or parts thereof, that have not been agreed with the Manufacturer shall relieve 
them from any and all responsibility and shall also cause the warranty to become null and void. 

 
 

PUMP DESCRIPTION 

 

Hawk high pressure piston pumps are volumetric pumps. 
As may be inferred from the header in this document, 4 pump series are described below, which are slightly different from one another. 

 

PUMPS NMT-EBCW 

This series consists of a brass head called 

ECOBRASS, 

plated with a chrome layer.

 

The piston seals are made of rubber fabric, while the other seals are made of NBR. 
The admitted work fluids are summarized in the table below 
 

PUMPS NMT-EBCH, XLTI-EBCH 

This pump consists of a brass head called ECOBRASS 
the piston seals are made of TEFLON (PTFE), while the other seals are made of FKM (Viton). 
The admitted work fluids are summarized in the table below. 

 

PUMP XLTI-ESA 

This pump consists of an AISI 316 stainless steel head. 
The piston seals are made of TEFLON (PTFE), while the other seals are made of HNBR. 
The admitted work fluids are summarized in the table below. 

 

TABLE SHOWING THE ADMITTED WORKFLOWS 

 

 

 

PUMP 

 

ADMITTED FLUIDS 

 
 

NMT-EBCW 

WATER 

DEMINERALISED/DESALTED WATER 

WATER WITH ALKALINE OR ACID DETERGENTS IN 0 TO 2% CONCENTRATION 

Содержание LEUCO HAWK NMT-EBCH Series

Страница 1: ...NAL INSTRUCTIONS LEUCO S p A Via Pietro Colletta 20 42124 Reggio Emilia RE ITALY Tel 0522 923011 Fax 0522 923030 923040 This manual is an integral part of the product and must always be available to t...

Страница 2: ...7 Fluids under pressure 10 3 SAFETY 11 3 1 Preliminary remarks 11 3 2 Residual risks 12 3 3 Personal protective equipment 12 3 4 Safe work procedures 12 3 5 Safety during lifting and handling operati...

Страница 3: ...orage and all the steps in the life cycle of the high pressure piston pumps series NMT EBCW NMT EBCH XLTI EBCH XLTI ESA Before starting any operation on the equipment both the operators and qualified...

Страница 4: ...te the hazard resulting from the presence of mechanical parts in motion during the pump work cycle e g transmission shafts gear motors etc SYMBOL MEANING COMMENT WARNING SIGNS SAFETY INFORMATION To in...

Страница 5: ...anty exists extending beyond the description above All pumps supplied by LEUCO have been carefully checked during production and subjected to testing cycles before shipment To achieve the best perform...

Страница 6: ...in parameters for the selection of a Hawk pump are the flow rate the pressure the rotation speed and the absorbed power The flow rate expressed in litres per minute is directly proportional to the rot...

Страница 7: ...CONNECTING ROD F PISTON related components G OIL LEVEL INDICATOR H DELIVERY VALVE I INLET VALVE The pumping action is implemented by a number of pistons which are linked to the motion transmission sh...

Страница 8: ...re piston pumps Series NMT EBCW NMT EBCH XLTI EBCH XLTI ESA Rev 0 Page 8 of 25 2 1 1 Technical characteristics The main dimensions and specifications are as follows SERIES NMT EBCW SERIES NMT EBCH Len...

Страница 9: ...sprohibited Instruction Manual High pressure piston pumps Series NMT EBCW NMT EBCH XLTI EBCH XLTI ESA Rev 0 Page 9 of 25 SERIES XLT EBCH Length 341 5 mm Depth 266 mm Height 168 mm Weight 20 5 Kg Capac...

Страница 10: ...n over time The lubrication oil which is specified later on in this manual was selected according to its compliance with the ATEX classification of the pumps Moreover overheating does not represent a...

Страница 11: ...ions changes and repairs must be carried out by qualified technicians who are authorised by the Manufacturer No intervention must be allowed on the equipment by unauthorised personnel Operators shall...

Страница 12: ...gns for personnel 3 3 Personal protective equipment Failure to wear personal protective equipment as specified in this section shall expose the operators to hazards The employer shall give personal pr...

Страница 13: ...on the quantity of goods to be shipped packages may be placed on a pallet for easier lifting and handling When removing the packaging check that the components are in good condition and in the right q...

Страница 14: ...de of TEFLON PTFE FKM Viton rubber fabric and NBR They must be disposed of in compliance with the specific instructions laid down in the existing laws No other products than those specified herein mus...

Страница 15: ...nds and burns e To protect the injured person against further harm f To prevent useless or harmful actions such as to give drinks to the injured person or to move him her to reduce dislocations and or...

Страница 16: ...ow for proper blood flow Treatment of deep wounds Protection against the risk of contagion is essential wear gloves and a face protector Dab at the bleeding point exerting a compression on the haemorr...

Страница 17: ...ible coupling for direct coupling with an electric motor Make sure the pulleys are aligned if pulley driven adjust the belt tension and provide adequate safety protection The pump must be installed ho...

Страница 18: ...k or waterworks B Shut off valve C Filter on inlet line D Auxiliary pump E Pressure gauge on intake line F Pressure gauge on delivery line G Safety valve H Pressure reducer I Regulating and bypass val...

Страница 19: ...e pump is fitted for all connections 5 2 Preliminary operations before first start up A set of checks and inspections have to be made before the pump is started up to prevent errors or accidents durin...

Страница 20: ...s shut down or not used for over six months so they must be changed The checks performed upon first start up sect 5 2 must be repeated whenever the pump is started after a long shutdown The oil level...

Страница 21: ...flow rate factor The table shows an example pump with Pmax 100 bar and Flow rate 15 l min Select the pressure value in the first line and move down the table until the flow rate factor that is closes...

Страница 22: ...IC SYSTEM X 1ST OIL CHANGE X CHANGE OIL X REPLACE SEALS X REPLACE CHECK VALVES X NOTE 1 Maintenance cycles must be performed based on the type of work to which the pump is subjected The work cycle tem...

Страница 23: ...from the level gauge located at the back of the pump body see sect 2 1 letterG Top up the oil if necessary using the same type specified in sect 3 7 Fill the oil through the plug featured in the top p...

Страница 24: ...if necessary The pressure regulation valve is not calibrated correctly or it is inefficient Calibrate the valve properly The piston seals are worn Check the condition of the seal housing Replace the...

Страница 25: ...ns and information The pump must be scrapped by skilled personnel in compliance with the laws existing on safety at work The disassembled components must be separated based on the type of constituting...