26
Maintenance
Factory Set Parameters (Auto Start/Stop with Lockout)
Factory Set Parameters
TIMER
VALUE
DESCRIPTION
Timer 1
04:00 Hours
Turns machine off after 4 hours of non-use. To restart push the
‘Pump On’ switch.
Timer 2
30:00 Seconds
Pump will run in bypass for 30 seconds before shutting off,
machine is still in standby mode. Pulling the gun trigger will
restart the pump.
Timer 3
15:00 Seconds
In case of pressure loss when machine is in standby, the pump
can run up to 15 seconds before resetting ‘Timer 1’ (lockout)
TIMER
VALUE
DESCRIPTION
Timer 1
03:00 Minutes
When machine is not in use, pump will run in bypass for 3
minutes and shut off. To restart push the ‘Pump On’ switch.
Timer 2
01:00 Hours
To operate in time delay mode timer 2 must be deactivated.
This is done by setting timer 2 to value greater than timer 1.
Timer 3
15:00 Seconds
Pump must run more than 15 seconds to reset timer 1.
Landa VNG Operator’s Manual 8.913-939.0 - AB