background image

     - 

4

DANGER

Risk of injury. Push the pedal for raising/ 
lowering the cleaning head with one foot 
only. The other foot must firmly be placed 
on the floor. 
In dangerous situations, release the safety 
switch/drive lever.

ATTENTION

Risk of damage. The suction bar must be 
lifted for reversing.

Note:

The device is designed and built in such a 
way that the cleaning head protrudes to-
wards the right. This enables working in a 
comfortable way close to the edges.

Plug in the Intelligent Key.

Preselect the speed on the drive speed 
rotary knob.

Turn the programme selection switch to 
transport mode.

Drive the machine.
Forwards:
Press the driving lever to the front. 
Backward: 
Press the driving lever to the rear. 

Note:

The device moves only when the driving le-
ver is moved by 15°. 

Stop the machine: Release driving lever. 

Open the lock of the fresh water reser-
voir.

Fill fresh water (maximum 60 °C) until 
the lower edge of the filling nozzle. 

Close the lock of the fresh water reser-
voir.

With automatic fill of fresh water reser-
voir (option)

Connect the hose to the automatic fill-
ing system and open the water supply 
(max. 60 °C, max. 5 bars).

Monitor the appliance - the automatic 
filling system will interrupt the water 
supply when the tank is full.

Shut off the water supply and discon-
nect the hose from the appliance.

WARNING

Risk of damage. Only use the recommend-
ed detergents. With other detergents, the 
operator bears the increased risk regarding 
the operational safety and danger of acci-
dent.
Only use detergents that are free from sol-
vents, hydrochloric acid and hydrofluoric 
acid.
Follow the safety instructions for using de-
tergents.

Note:

Do not use highly foaming detergents.

Recommended detergents:

Detergent is added to the fresh water on 
the way to the cleaning head with the help 
of a dosaging device.

Note:

The dosing unit can be used to add 3% de-
tergent at maximum. With higher dosage 
the detergent must be put into the fresh wa-
ter tank.

Place the detergent bottle into the holder.

Close the bottle lid.

Insert the suction hose of the dosaging 
equipment into the bottle.

Note:

If the fresh water tank is empty, then the 
function of adding detergent gets deactivat-
ed. The cleaning head continues to work 
without the addition of any liquid.

Add the detergent to the fresh water 
reservoir.

Adjust the water quantity using the reg-
ulating button according to the dirt on 
the floor covering. 

Note:

Carry out initial cleaning attempts with low 
water volume. Increase water volume step-
by-step until the desired cleaning result is 
achieved.
The detergent pump of the dosing equip-
ment does not start working until a mini-
mum water volume is present.

To improve the vacuuming result on tiled 
floors the vacuum bar can be turned to an 
oblique position of up to 5°.

Loosen the wing nuts.

Turn the vacuum bar.

Tighten the wing screws.

If the vacuum result is unsatisfactory the in-
clination of the straight vacuum bar can be 
modified.

Adjust the rotary handle to incline the 
suction bar.

Parameters for the different cleaning pro-
grammes are preset in the appliance.
Depending on the authorisation of the yel-
low Intelligent Key, individual parameters 
can be changed.
If you wish to permanently change the pa-
rameters, you must use a grey Intelligent 
Key. This adjustment procedure is de-
scribed in the section "Grey Intelligent 
Key“.

Note:

Almost all displayed text regarding param-
eter adjustment is self-explanatory. The 
only exception is the parameter FACT:
– Fine Clean: Lower brush speed for re-

moving the grey film on fine stone 
floors. 

– Whisper Clean: Medium brush speed 

for regular cleaning with reduced noise 
level. 

– Power Clean: High brush speed for pol-

ishing, crystallising and sweeping. 

Turn the program selection switch to 
the desired cleaning program. 

Turn the info button until the desired pa-
rameter is displayed.

Press Info button - the set value blinks.

Set the desired value by turning the info 
button.

Confirm the changed setting by press-
ing the Info button or wait till the set val-
ue is automatically accepted after 10 
seconds. 

ATTENTION

Risk of damage to the floor covering. Do 
not operate the appliance on the spot.

Turn the program selection switch to 
the desired cleaning program. 

Press the pedal for lowering the clean-
ing head downwards slightly and then 
move it to the left. This unlocks the ped-
al. Release the pedal slowly upwards.
The cleaning head is lowered.

Note:

The brush motor comes to a halt when the 
machine stops and when there is overload.

Arrest the lever in the desired position.
Upper position: higher contact pressure
Lower position: reduced contact pres-
sure

Pull the lever out and press it down; the 
vacuum bar is lowered.

Note:

– For cleaning tiled floors, adjust the 

straight suction bar in such a way that 

Operation

Driving

Filling in detergents

Fresh water

Detergent

Application

Detergent

Routine cleaning of all water 
resistant floors

RM 746
RM 780

Routine cleaning of glossy 
surfaces (e.g. granite)

RM 755 es

Routine cleaning and basic 
cleaning of industrial floors

RM 69 ASF

Routine cleaning and basic 
cleaning of fine stoneware tiles

RM 753

Routine cleaning of tiles in 
sanitary areas

RM 751

Cleaning and disinfection in 
sanitary areas

RM 732

Removal of coating from all al-
kali-resistant floors (e.g. PVC)

RM 752

Removal of coating from li-
noleum floors

RM 754

Appliance with dosing equipment DOSE 
(option)

Models without dosing equipment

Setting the water quantity

Setting the Vacuum Bar

Oblique position

Inclination

Setting the parameters

With yellow Intelligent Key

Cleaning

Lower the cleaning head

Adjusting the brush contact pressure

Lower the vacuum bar

6

EN

Содержание B 60 W Bp

Страница 1: ...B 60 W Bp 001 59645740 07 17...

Страница 2: ...2...

Страница 3: ...ww kaercher com Use this appliance only as directed in these operating instructions The appliance may only be used for the cleaning of hard surfaces that are not sensitive to moisture and polishing op...

Страница 4: ...pole fuse 23 Battery 24 Fresh water level display 25 Pedal for raising lowering the cleaning head 26 Lever to adjust the brush contact pres sure 27 Rotary handle to incline the vacuum bar 28 Wing nut...

Страница 5: ...folded up Insert the plug of the connecting cable into the socket The charging process will start Note The selected battery will be dis played during charging Charge until the display shows a full ch...

Страница 6: ...um bar can be turned to an oblique position of up to 5 Loosen the wing nuts Turn the vacuum bar Tighten the wing screws If the vacuum result is unsatisfactory the in clination of the straight vacuum b...

Страница 7: ...ameters that are adjusted with the grey Intelligent Key are kept until another set ting is selected Turn the program selection switch to the desired cleaning program Turn the info button until Cleanin...

Страница 8: ...es Clean the brush tunnel only BR model For long periods of disuse only turn the device off when the battery is fully charged Fully recharge the battery at least every month Have the prescribed inspec...

Страница 9: ...nce can be compro mised ensure a safe stance Possibly support the rear to prevent tipping Please observe the following warning notes when handling batteries DANGER Risk of explosion Do not place tools...

Страница 10: ...te water tank Loosen the tank lock and tilt the tank upwards Clamp off the minus pole of the battery Clamp off the remaining cables from the battery Remove the support blocks or the foam pieces CAUTIO...

Страница 11: ...e water distribution strip from the cleaning head and clean water canal only R cleaning head Check hoses for blockages clean if required Do not add detergents Increase the water volume to activate the...

Страница 12: ...normal to heavily dirtied floors 20 80 96 BD appliances B 60 W Bp disc brush accessories Description Part no Working width 550 mm Part no Working width 650 mm Description Packaging unit Appliance requ...

Страница 13: ...ed output W 300 Suction engine output W 580 Brush engine output W 2 x 600 Vacuuming Vacuum power air volume max l s 22 Vacuuming power negative pressure max kPa mbar 16 7 167 Cleaning brushes Brush sp...

Отзывы: