DANGER

Risk of injury! Before working on the appli-
ance, remove the Intelligent Key and the 
mains plug of the charger.

Drain and dispose of the dirt water and 
the residual fresh water.

If the display shows different error messag-
es or if the error cannot be remediated:

Remove the Intelligent Key.

Wait for 10 seconds.

Plug in the Intelligent Key.

If the fault recurs, call customer service.

Faults

Faults with display

Display

Remedy

ERR_I_BÜRSTE_049

Check if foreign matters block the brushes; remove foreign matter if required.

ERR_I_TURB_050

Check suction turbine for contamination and clean it if necessary.

ERR_U_BATT_001

Check battery; charge it if required. 

Faults without display on the console

Fault

Remedy

Appliance cannot be 
started

Stand-by. Turn the appliance off and reinsert the Intelligent Key. 
Turn the program selection switch to the desired programme.
Check battery; charge it if required. 
Make sure that all battery terminals are connected.

Insufficient water quan-
tity

Check fresh water level, refill tank if necessary.
Increase the water volume on the regulating knob for water volume.
Unscrew the lock of the fresh water reservoir. Remove and clean the fresh water filter. Insert the filter and screw 
in the lock.
Remove the water distribution strip from the cleaning head and clean water canal (only R cleaning head).
Check hoses for blockages; clean if required.

Do not add detergents Increase the water volume to activate the dosing pump.

Check the detergent level

Insufficient vacuum per-
formance

Clean the seals between waste water tank and cover and check for tightness, replace if required.
Wastewater reservoir is full; shut off the appliance and empty the wastewater reservoir
Check protective turbine strainer for soiling, clean if necessary.
Clean the vacuum lips on the vacuum bar, replace if required
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.

Insufficient cleaning re-
sult

Check the brushes for wear, replace if required.

Brushes do not turn

Check if foreign matters block the brushes; remove foreign matter if required.
If over-current switch in the electronics system has been triggered, turn programme selection switch to "OFF". 
Afterwards, set it back to the desired programme.

Vibrations during clean-
ing

You might need to use softer brushes.
Cleaning head has play, open the excenter lever and press the cleaning head all the way against the push han-
dle, close the excenter lever.

In case of faults that cannot be remedied using the table below please contact the customer service. 

11

EN

Содержание B 60 W Bp

Страница 1: ...B 60 W Bp 001 59645740 07 17...

Страница 2: ...2...

Страница 3: ...ww kaercher com Use this appliance only as directed in these operating instructions The appliance may only be used for the cleaning of hard surfaces that are not sensitive to moisture and polishing op...

Страница 4: ...pole fuse 23 Battery 24 Fresh water level display 25 Pedal for raising lowering the cleaning head 26 Lever to adjust the brush contact pres sure 27 Rotary handle to incline the vacuum bar 28 Wing nut...

Страница 5: ...folded up Insert the plug of the connecting cable into the socket The charging process will start Note The selected battery will be dis played during charging Charge until the display shows a full ch...

Страница 6: ...um bar can be turned to an oblique position of up to 5 Loosen the wing nuts Turn the vacuum bar Tighten the wing screws If the vacuum result is unsatisfactory the in clination of the straight vacuum b...

Страница 7: ...ameters that are adjusted with the grey Intelligent Key are kept until another set ting is selected Turn the program selection switch to the desired cleaning program Turn the info button until Cleanin...

Страница 8: ...es Clean the brush tunnel only BR model For long periods of disuse only turn the device off when the battery is fully charged Fully recharge the battery at least every month Have the prescribed inspec...

Страница 9: ...nce can be compro mised ensure a safe stance Possibly support the rear to prevent tipping Please observe the following warning notes when handling batteries DANGER Risk of explosion Do not place tools...

Страница 10: ...te water tank Loosen the tank lock and tilt the tank upwards Clamp off the minus pole of the battery Clamp off the remaining cables from the battery Remove the support blocks or the foam pieces CAUTIO...

Страница 11: ...e water distribution strip from the cleaning head and clean water canal only R cleaning head Check hoses for blockages clean if required Do not add detergents Increase the water volume to activate the...

Страница 12: ...normal to heavily dirtied floors 20 80 96 BD appliances B 60 W Bp disc brush accessories Description Part no Working width 550 mm Part no Working width 650 mm Description Packaging unit Appliance requ...

Страница 13: ...ed output W 300 Suction engine output W 580 Brush engine output W 2 x 600 Vacuuming Vacuum power air volume max l s 22 Vacuuming power negative pressure max kPa mbar 16 7 167 Cleaning brushes Brush sp...

Отзывы: