30
DN1611-1809
Configuring with a Static IP Address (continued)
4. In the
Ethernet #1
section:
•
The
MAC Address
of the KT-NCC is already configured. The MAC address is found on the
top right of the KT-NCC circuit, under Ethernet Port #1, see Figure 22: on Page 39.
•
Ensure that the
DHCP
parameter is
Disabled
.
•
Enter the
IP address
of the KT-NCC that you received from the Network Administrator.
•
Enter the KT-NCC
Subnet Mask
.
•
The
Port
number is already configured. It is advisable to always use the default value
18710
.
5. The fields in the
Ethernet #2
section are already configured. You do not have to change these
parameters.
6. Click
Save Configuration to KT-NCC
. A message showing that the configuration is saved and that the
KT-NCC is reinitializing will appear on the screen.
Figure 16: Save Web Configuration Page
7. Click on
Click here to return
. The screen will return to the KT-NCC Web Configuration tool main
window. Meanwhile, the KT-NCC will reset.
•
The blue Heartbeat LED of the KT-NCC will blink quickly to signal that the KT-NCC is in
reset mode.
•
The blue Heartbeat LED of the KT-NCC will remain lit for 15 seconds to signal that the KT-
NCC is in startup mode.
•
The blue Heartbeat LED of the KT-NCC will blink 4 times to signal that the KT-NCC has
reset but it is not yet registered on the EntraPass server. (Hard reset mode
.)
Note:
For details, refer to Hearbeat Blue LED Patterns on Table 7 on Page 43.
8. Close the KT-NCC Web Configuration window. Once the KT-NCC is registered on the server, you will
no longer be able to access the Web Configuration Page.
9. Disconnect the cable of Ethernet port #2.
10.Connect the network cable on Ethernet port #1.
11. Register the KT-NCC in EntraPass Global Edition software (See instructions on page 25).
Using the KT-
Finder
1. Connect the network cable to the Ethernet Port #1.
2. Select the
KT-NCC
from the devices list. Enter the MAC address of Ethernet Port #1 and click on
Connect
.
Содержание KT-NCC
Страница 1: ...DN1611 1809 KT NCC Network Communications Controller Installation Manual ...
Страница 41: ...DN1611 1809 41 Figure 24 KT NCC Wiring Diagram for Europe and Asia ...
Страница 45: ...DN1611 1809 45 ...
Страница 46: ... 2018 Tyco Security Products All Rights Reserved www kantech com DN1611 1809 ...