COLD WEATHER PRECAUTIONS

It is important you keep your flue gas analyser in a warm place overnight.

Electronic devices that become really cold, by being left in a vehicle

overnight, suffer when taken into a warm room the next morning.

Condensation may form which can affect the analyser performance &

cause permanent damage.

Electrochemical sensors used in flue gas anlysers can be affected by

condensation or water being sucked into the analyser, as the small

apertures on top of sensors can become blocked with water, stopping

sensors seeing flue gas. When this happens, oxygen or carbon dioxide

reading will display as “—” & sensors may be permanently damaged.

If you think that your analyser is affected by condensation or water

ingress, it may be possible to rectify the problem yourself. Simple leave

the analyser running in a warm place, with the pump ‘ON’ sampling 

fresh air for a few hours (use mains adapter/battery charger if needed). 

If, after doing this, you still experience problems please contact our 

Service Centres.

Содержание KANE458s

Страница 1: ...KANE458s Flue Gas Analyser with direct CO2 measurement and CO sensor protection Stock No MAN00232 Rev 1 00721 JULY 2021 Kane International Ltd...

Страница 2: ...ETY 10 FIRST TIME USE 11 GENERAL OPERATING PRINCIPLE 11 QUICK START 11 USER INTERFACE 11 STATUS 12 STATUS BAR 12 STATUS BAR LAYOUT 12 STATUS BAR MESSAGE AREA 13 STATUS BAR ICONS 14 STATUS BAR ICON LEV...

Страница 3: ...ENDING OR STORING REPORTS 21 PRESSURE MEASUREMENT GOOD PRACTICE 22 LARGE BORE TUBING ISSUES 22 TESTS 22 COMMISSIONING TEST 22 TEST 1 CHECK THE APPLIANCE AT MAX GAS RATE 22 TEST 2 23 TEST 3 CHECK APPLI...

Страница 4: ...teries Your KANE458s has a low gas flow detector switching off the analyser pump if it detects water entering the analyser from an overfilled water trap Your KANE458s has a large 6 line display showin...

Страница 5: ...5 KANE 458s MANUAL ANALYSER FEATURES AND KEYPAD...

Страница 6: ...rint a report Choose PRINTER or WIRELESS to KANE s Apps Navigate up Short press to scroll up Enter button Use to select the current option Navigate down Short press to scroll down Data hold Short pres...

Страница 7: ...t temperature T2 Pressure connection P1 Pressure connection P2 Differential Flue gas inlet On Off Function buttons see below Water trap particle filter Rotary dial Red connector plugs into Flue Gas In...

Страница 8: ...8 KANE 458s MANUAL Watertrap drain with red plug Thermocouple Thermocouple Wire Stainless Steel Shaft Depth Stop Cone Gas Path Magnets x2...

Страница 9: ...uring they are fitted with correct battery polarity Replace battery cover protective rubber cover TIME AND DATE After changing batteries reset your analyser time date CHARGING NIMH BATTERIES Your anal...

Страница 10: ...to known gas mixtures to change the output of all sensors present Note This is different from a calibration where the instrument is also exposed to known gas mixtures but allowed to settle to a steady...

Страница 11: ...egrity of your stored data GENERAL OPERATING PRINCIPLE Using your analyser is simple with the rotary dial and user interface Most tests can be made with little user activity Your analyser status bar o...

Страница 12: ...on due Status bar Current fuel selection use status bar menu to change fuel selection STATUS BAR The Status bar shows your analyser status and offers options based on your settings Navigate through th...

Страница 13: ...time stamp of held data Displays current time CALIBRATION DUE WARNING MESSAGE AIR PURGE SNOOZE TIMER LOW BATTERY WARNING MESSAGE Display alternates between calibration due symbol current time Display...

Страница 14: ...ST PUMP LOGGED DATA SENDING DATA BATTERY STATUS BAR MENU OPTIONS Status Bar offers helpful menu items based on what s displayed on your analyser screen STANDARD OPTIONS Date Displays selected fuel typ...

Страница 15: ...l to any position but any changes not entered will not be stored MENU ITEMS MENU ITEM MENU TEXT OPTIONS COMMENTS TIME TIME HH MM SS format E g 7am 07 00 00 7pm 19 00 00 DATE DATE DD MM YY format HEADE...

Страница 16: ...ntil you use KANE LINK to remove them If on they replace or add to you analyser measurements your analyser makes See page 29 to add or remove optional KANE LINK devices MEASURING FLUE GASSES After cou...

Страница 17: ...xpected range SENDING OR STORING TEST REPORTS Press and release button then select your optional KANE IRP printer or your App using or then USING YOUR KANE INFRARED PRINTER Switch on your printer and...

Страница 18: ...irelessly connected DTHA2 anemometer it will automatically display its readings on AUX when on To stop this simply switch off the DTHA2 ROTATE DIAL TO 02 EFF ROTATE DIAL TO RATIO STORED MEMORY LOGS RE...

Страница 19: ...reports select VIEW option from LOGS Menu No of Combustion logs stored No of Auxiliary logs stored No of Pressure Temperature logs stored Total memory used Menu options View stored reports if availab...

Страница 20: ...from status bar View stored Combustion Reports if any View stored Auxiliary Reports if any View stored Pressure Temperature Reports if any Returns to previous menu Report time and date alternates bet...

Страница 21: ...r hose to connect to P1 for single pressure or P1 P2 for differential pressure TEMPERATURE PRESSURE DISPLAY SENDING OR STORING REPORTS Press and release then select either your optional KANE IRP print...

Страница 22: ...tests TESTS COMMISSIONING TEST Your analyser commissioning test uses the test outlined in the UK s TB143 but is not a substitute for an appliance manufacturer instructions Rotate dial to COM TEST pos...

Страница 23: ...ATE WHERE POSSIBLE Select NEXT on status bar using and The appliance is stable at minimum gas rate measure CO CO RATIO levels these must be within the manufacturer instructions If manufacture instruct...

Страница 24: ...ssure then press to start the let by test display shows If let by test fails rotate dial to another position to stop the test If Let by test passes adjust gas pressure for the tightness test press to...

Страница 25: ...ORTS Let by Tightness reports are automatically stored Page 18 20 explains how to view print stored reports Press and release then select either your optional KANE IRP printer or wirelessly to your AP...

Страница 26: ...ALARM 30 ppm MIGRATION TEST 15 minute test with results stored every minute LIMIT 10ppm ALARM 30 ppm TYPE C SEALED APPLIANCE 15 minute test with results stored every minute LIMIT 10ppm ALARM 30 ppm TY...

Страница 27: ...e Room CO tests are automatically stored in your analyser memory as a log number You can send your Room CO test log to your optional KANE IRP 2 print er by pressing or wirelessly using to your App See...

Страница 28: ...28 KANE 458s MANUAL Auxiliary Commission Combustion Let by Tightness Type A Pressure Temp Sweep Test PRINTOUTS...

Страница 29: ...ices select LINK using buttons WPCP2 WIRELESS PIPE CLAMP To add select it then enter its serial number using buttons Enter its serial number using buttons Each clamp serial number must be 10 digits lo...

Страница 30: ...tery Life 8 hours continuous with pump on Certification The KANE458s is independently tested certified to EN 50379 Parts 1 3 in accordance to 1st German Federal Emission Control Ordinance Bim5chV SPEC...

Страница 31: ...GE RESOLUTION ACCURACY Operating Conditions Temperatures 0 45 C Humidity 15 to 90 RH non condensing Power Supply Rechargeable batteries USB Charging Physical Characteristics Weight Approx 0 625g Dimen...

Страница 32: ...following harmonised standards technical specifications have been applied CERTIFICATION The KANE458s is independently tested certified to EN 50379 Parts 1 3 in accordance to 1st German Federal Emissio...

Страница 33: ...LIBRATE RECERTIFY All analysers pressure meters should be recertified annually Extend your KANE analyser pressure meter s no quibble warranty up to 10 years by returning your analyser pressure meter v...

Страница 34: ...ts new owner can also benefit The fastest way to manage your analyser recertification with FREE postage using www kane co uk There are different KAM options we d be delighted to discuss your individua...

Страница 35: ...35 KANE 458s MANUAL KAM Your support our way...

Страница 36: ...o uk Select FREEPOST for tracked carriage UK mainland only Your analyser will be despatched on the same day we receive it Book pay to Service Recertify via your KAM dashboard OR YOUR MONEY BACK GUARAN...

Страница 37: ...m room the next morning Condensation may form which can affect the analyser performance cause permanent damage Electrochemical sensors used in flue gas anlysers can be affected by condensation or wate...

Страница 38: ...38 KANE 458s MANUAL THIS PRODUCT CONFORMS WITH THE FOLLOWING PLEASE RECYCLE PACKAGING MADE IN THE UK...

Страница 39: ...re use please register on our website www kane co uk Scan the QR code to go directly to register your product online Kane International Ltd Kane House 11 Bessemer Road Welwyn Garden City Hertfordshire...

Отзывы: