23
KANE 458s MANUAL
TEST 2
Insert your flue probe into the appliance exhaust outlet to measure CO,
CO₂ & RATIO levels – these must be within manufacturer instructions. If
manufacturer instructions are not available CO must be under 350ppm &
RATIO under 0.0040.
TEST 3 – CHECK APPLIANCE AT MINIMUM GAS FLOW RATE
WHERE POSSIBLE
Select NEXT on status bar using and
.
The appliance is stable at minimum gas rate, measure CO, CO₂ & RATIO
levels – these must be within the manufacturer instructions.
If manufacture instructions are not available, CO must be under 350ppm
& RATIO under 0.0040.
To finish press
. To continue next press followed by
.
TEST 4 – MEASURE APPLIANCE FLOW & RETURN
TEMPERATURES
All measured readings are logged & can be printed to our optional KANE
IRP-2 printer or wirelessly to our KANE Apps. See page 18-20.