background image

25

22. GENERATOR TRANSPORTATION

For easy generator transportation use packaging, which generator was sold in. Secure 

the box with the generator to avoid tipping ir on the side of the carriage. Before 

moving the generator drain the fuel and disconnect the terminals of the battery.

To move the generator from one place to another lift it by holding the frame. Be careful 

- the generators are heavy (40 to 90 kg). At least two men are needed to move the 

generator. Be careful, do not expose your feet under the frame of the generator.

23. POSSIBLE FAILURES AND SOLUTIONS

Typical failures

Possible reason

Solution

Engine does not

starting

Engine starting swinch set 

to OFF position

Set the engine starting 

switch to ON

Fuel valve set to off position

Turn the valve to ON position

Air flap is opened

Shut the air flap

No fuel

Add fuel

Low-quality or dirty fuel is in

engine

Change the fuel

sparking plug smoked or 

corrupted distance between 

contacts is not nominal

Clean or replace the plug; 

Set proper distance between 

contacts

Low engine power / 

heavy starting

Dirt in fuel tank

Clean the fuel tank

Dirt in the air filter

Clean the air filter

Water in a fuel tank/

carburetor; carburetor  is 

jammed

Empty the fuel tank, 

carburetor

Distance between contacts 

of a sparking plug is not 

nominal

Set proper distance between

contacts

Engine overheated

Cooling fins are dirty

Clean the cooling fins

Air filter is dirty

Clean the air filter

No voltage while

working engine

Circuit breaker is active

Turn on the cricuit breaker

Connected cables are 

corrupted

Check the cables;

if using extension cord, 

change it

Plugged device failure

Try to connect other devices

Connected devices

are not working

while generator is

running

Generator is overloaded

Unplug some devices to 

reduce load

Short circuit occured in one of

the devices connected

Unplug that device to restore 

the stability of a system

Air filter is dirty

Clean the air filter

Repetitions of an engine are 

lower than nominal

Contact the service center

Содержание KS 3000

Страница 1: ...enerator Dual fuel generator Instruction Please read this manual before use ENG KS 3000 KS 3000E KS 7000 KS 7000E KS 7000E 3 KS 7000E ATS KS 7000E 3 ATS KS 7000E 1 3 KS 10000E 1 3 KS 10000E KS 10000E 3 KS 10000E ATS KS 10000E 3 ATS ...

Страница 2: ...3 Generator panel for models KS 7000E 1 3 KS 10000E 1 3 14 9 4 Digital display of gasoline generators 15 10 COMMISSIONING 15 11 BEFORE STARTING 16 11 1 Check the fuel level 16 11 2 Check the oil level 16 12 ENGINE START 16 12 1 Gasoline generator engine start 17 12 2 Running generator on liquefied gas 17 12 3 Generator launch in ATS mode for generators with ATS 18 13 GENERATOR CONNECTION 19 14 STO...

Страница 3: ...tegrity and avoid any possible injuries we strongly recommendYou to carefully read this manual before operating the generator ABBREVIATIONS MEANING KS Generator model Е Electro start G Dual fuel type LPG gasoline ATS Automatic transfer switch Read carefully these instructions Pay special attention to information that begins with these characters words Failure to follow the recommendations marked w...

Страница 4: ...cian in accordance with all electrical rules and regulations Connect the generator to the protective ground before operation Do not connect or disconnect a generator to electricity consumers which are placed in water on a wet or damp soil Do not touch parts of the generator under voltage Connect the generator to those customers only which meet the electrical characteristics and the rated power of ...

Страница 5: ...ing the tank all excessive fuel spillage are to be removed from the surface It is forbidden to use kerosene or other fuel types Observe the fuel tank refilling Do not allow overfilling All explosive and flammable materials or substances are to be kept away from the generator for its engine produces heat during operation It is forbidden to touch the exhaust system during the generator start and in ...

Страница 6: ...e manual before using the device g Do not touch the generator with wet or dirty hands h Follow fire safety rules do not use open flames near the generator i Please don t touch The muffler heats up when running the generator a b c f e d a Useprotectiverubbergloveswhileworking with battery Batterycontainsacidelectrolyte whichisdangerous Ifcontact withskinorface occured rinse it off immediately with ...

Страница 7: ...erent models this table is different All charachtetistics are given in the Specifications Indicates the position of the fuel tap Position ON opened position OFF closed Note which direction you should open air dampers Fuel level indicator The icon on the left indicates that the tank is full the icon on the right that the tank is empty Maintenance information translated into the language of the coun...

Страница 8: ... switch 10 Fuel level indicator 11 Silencer 12 Alternator 13 Sparking plug 5 MAIN OVERVIEW pic 4 Manufacturerreservestherighttomakechangesand orimprovements indesign componentsset andtechnicalattributeswithoutnotice andwithoutincurringobligation Thepicturesinthismanualare schematicalandmaynotmatchtheparametersoforiginalproduct IMPORTANT 1 2 3 4 5 6 7 8 9 10 13 11 12 ...

Страница 9: ... fuel generators additionally equipped with reductor for stable LPG supply pic 5 reductor LPG supply hose BE ADVISED It is strongly forbidden to use gasoline and LPG simultaneously While using a gasoline source the LPG supply should be stopped The same situation is with liquid gas powering ATTENTION DANGER 7 COMPONENTSOFSET 1 Generator 2 Packaging 3 Operating Instructions 4 Key candle 5 Keys to ru...

Страница 10: ... 69 94 69 94 Power output V А 12 8 3 12 8 3 12 8 3 Engine model KS 230 KS 230 KS 230 Engine type gasoline 4strokecycle engine gasoline 4strokecycle engine LPG gasoline 4strokecycle engine Engine power hp 7 0 7 0 7 0 Crank case volume cm3 0 6 0 6 0 6 Enginecylindervolumecm3 208 208 208 Power output controller AVR AVR AVR Engine start manual manual electro manual Power factor cosφ 1 1 1 Dimensions L...

Страница 11: ...r output V А 12 8 3 12 8 3 12 8 3 Engine model KS 410 KS 410 KS 410 Engine type gasoline 4strokecycle engine gasoline 4strokecycle engine gasoline 4strokecycle engine Engine power hp 13 0 13 0 13 0 Crank case volume cm3 1 1 1 1 1 1 Engine cylinder volume cm3 389 389 389 Power output controller AVR AVR AVR Engine start manual manual electro manual electro Power factor cosφ 1 1 1 Dimensions L W H mm...

Страница 12: ...tput V А 12 8 3 12 8 3 12 8 3 Engine model KS 410 KS 410 KS 410 Engine type gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine Engine power hp 13 0 13 0 13 0 Crank case volume cm3 1 1 1 1 1 1 Engine cylinder volume cm3 389 389 389 Power output controller AVR AVR AVR Engine start manual electro manual electro auto manual electro auto Power factor cosφ 0 8 1...

Страница 13: ... 8 3 12 8 3 12 8 3 12 8 3 Engine model KS 460 KS 460 KS 460 KS 460 Engine type gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine gasoline 4 stroke cycle engine Engine power hp 18 0 18 0 18 0 18 0 Crank case volume cm3 1 2 1 2 1 2 1 2 Enginecylindervolumecm3 440 440 440 440 Power output controller AVR AVR AVR AVR Engine start manual electro manual electro ...

Страница 14: ...AVR Engine start manual electro manual electro Power factor cosφ 1 0 8 1 0 8 Dimensions L W H mm 700 545 590 700 545 590 Weight kg 81 8 95 Protection class IP23M IP23M Altitude MAX m 1000 1000 Relative humidity 95 95 Acceptable deviation of a current is 5 Toensurethereliabilityofthegeneratorandincreaseitslifespan thepeakcapacities may be slightly limited by circuit breakers Theoptimumoperatingcond...

Страница 15: ...0E ATS KS 10000E 3 ATS pic 7 1 LED display 2 Emergency circuit breaker 3 Sockets 4 Engine start key ON OFF 5 Direct current sockets 12V 6 Grounding 7 ATS switch 8 ATS indicator 9 ATS connectors 1 LEDdisplay 2 Emergencycircuitbreaker 3 Sockets 4 Grounding 5 3phase 1phasemodeswitch position1 400V position0 off position2 230V 6 Directcurrentsockets12V 7 Enginestartkey 1 2 3 9 8 6 5 4 7 9 3 GENERATOR ...

Страница 16: ...supplied without fuel Before the operation please fill the fuel Guidelines for filling are below Generators are supplied without motor oil The generator casing may contain residues of oil after tests conducted during production Before starting to use the generator be sure to pour oil Recommendations on oil and it s filling process are below Follow maintenance recommendations during the first month...

Страница 17: ...tor has not been used for a long time try charging the battery with the battery charger not included Fuel tank cap FILLTO HERE 12 ENGINE START Beforestartingtheenginepleasemakesurethatpowerofinstrumentsor electricconsumerscompliestothecapacitiesofthegenerator Itisforbidden toexceeditsnominalcapacity Donotconnectdevicesbeforestartingthe engine Inpowersupplymodewithinrangefromnominaltillmaximum powe...

Страница 18: ...t the hose to the gas cylinder 2 Open the gas supply valve on the tank make sure there are no gas leaks 3 Usethevalveontheintegratedgearboxtoletoutairfromthehoseconnection press the lowering valve button on the generator gear 2 3 times to start the engine 4 Set the fuel valve on fuel tank to the closed position there should be no fuel in the carburetor 5 Set the air flaps in the middle position Af...

Страница 19: ...r so that it begins to supply power to devices connected to it When the power supply from the main network is renewed the generator system turns off and the voltage to consumers goes from the main network In order to run the generator without ATS mode do not set the ATS switch to AUTO mode 13 3 GENERATORLAUNCHINATSMODE FORGENERATORSWITHATS Built inautomaticstartsystemallowscontrollingthegenerators...

Страница 20: ... of electricity Power supply Power supply Electrical counter Electrical counter Neutral channel for connection Grounding Connectionofthegeneratorwiththebuilt inATStotheconsumersofelectricityandthecentralpowersupply 13 1 SCHEME OF CONNECTION OF A SINGLE PHASE GENERATOR 13 2 CONNECTION SCHEME OF THE THREE PHASE GENERATOR L Line N Neutral L 1 3 Line N Neutral Neutral 19 ...

Страница 21: ... IMPORTANT IMPORTANT 15 TECHNICAL MAINTENANCEWORKS Works specified in Technical maintenance section are to be regularily performed If the end user has no means for performing regular maintenance independently it is necessary to address the official service centre to place an order for such works performance In case of any damages occurred due to non performance of regular maintenance works the man...

Страница 22: ...safety requirements and technical maintanance rules First of all this applies to use of lubricants gasoline and motor oils forbidden by the manufacturer device technical alterations equipment operations against its intended use indirect damages caused by operating faulty equipment 16 MAINTENANCE SCHEDULE Node Service type First month or 20 hours Before starting Each month or after 20 working hours...

Страница 23: ...ntanance schedule To replace engine oil perform the following actions 1 Wearprotectiveglovestoavoidgettingoilontheskin 2 Place a drain oil holding tank under the engine 3 Turn the drain cap located in the engine under the oil depth gage cap by means of a hexagon spanner 10 mm for all verifications of KS 3000 4 Wait till the oil drains 5 Replace the drain cap and tighten it well 6 Pleae drain the o...

Страница 24: ...rator operation every 10 hours in unusually dusty conditions pic 15 IMPORTANT wash wring soak wring 2 1 4 3 cap spring cap spring air filter air filter cap 19 SPARKPLUGSTECHNICALMAINTENANCE Spark plug is an importaint element providing the correct engine operation It has to be intact without soot deposits and to have a correct gap Spark plug verification 1 Remove the cap from the spark plug 2 Remo...

Страница 25: ...lower gaswillevaporate Warning Generator is to remain ready for operation at all times Therefore in case of device malfunctions they are to be repaired before dismounting the generator for storage Beforelong termgeneratoridletime performthefollowingactions Generator and engine external parts especially the cooling radiators are to be thoroughlycleaned Carburetorfloatchamberscrewhastoberemovedandth...

Страница 26: ...nce between contacts is not nominal Clean or replace the plug Set proper distance between contacts Low engine power heavy starting Dirt in fuel tank Clean the fuel tank Dirt in the air filter Clean the air filter Water in a fuel tank carburetor carburetor is jammed Empty the fuel tank carburetor Distance between contacts of a sparking plug is not nominal Set proper distance between contacts Engine...

Страница 27: ... Radio 50 250 TV set 100 400 Refrigerator 100 150 Oven 1000 2000 Freezer 100 400 Drill 400 800 Hammer drill 600 1400 Grinding machine 300 1100 Circular saw 750 1600 Electro planer 400 1000 Electro jigsaw 250 700 Angle grinder 650 2200 Compressor 750 3000 Water pump 750 3900 Electric sawing machine 1800 4000 High pressure machine 2000 4000 Electric lawn 750 3000 Air conditioner 1000 5000 Electric p...

Страница 28: ...ater ice formation provided there are foreign objects inside the unit If the product has been improperly installed and connected to the mains supply or misused If the claimed malfunction cannot be diagnosed or demonstrated If proper operation of the product can be restored following cleaning from dust and dirt appropriate adjustment maintenance oil change etc If the product is used for business re...

Страница 29: ......

Страница 30: ...Germany ks power de info dimaxgroup de Poland ks power pl info pl dimaxgroup de Ukraine ks power com ua sales ks power com ua CONTACTS ...