25
22. GENERATOR TRANSPORTATION
For easy generator transportation use packaging, which generator was sold in. Secure
the box with the generator to avoid tipping ir on the side of the carriage. Before
moving the generator drain the fuel and disconnect the terminals of the battery.
To move the generator from one place to another lift it by holding the frame. Be careful
- the generators are heavy (40 to 90 kg). At least two men are needed to move the
generator. Be careful, do not expose your feet under the frame of the generator.
23. POSSIBLE FAILURES AND SOLUTIONS
Typical failures
Possible reason
Solution
Engine does not
starting
Engine starting swinch set
to OFF position
Set the engine starting
switch to ON
Fuel valve set to off position
Turn the valve to ON position
Air flap is opened
Shut the air flap
No fuel
Add fuel
Low-quality or dirty fuel is in
engine
Change the fuel
sparking plug smoked or
corrupted distance between
contacts is not nominal
Clean or replace the plug;
Set proper distance between
contacts
Low engine power /
heavy starting
Dirt in fuel tank
Clean the fuel tank
Dirt in the air filter
Clean the air filter
Water in a fuel tank/
carburetor; carburetor is
jammed
Empty the fuel tank,
carburetor
Distance between contacts
of a sparking plug is not
nominal
Set proper distance between
contacts
Engine overheated
Cooling fins are dirty
Clean the cooling fins
Air filter is dirty
Clean the air filter
No voltage while
working engine
Circuit breaker is active
Turn on the cricuit breaker
Connected cables are
corrupted
Check the cables;
if using extension cord,
change it
Plugged device failure
Try to connect other devices
Connected devices
are not working
while generator is
running
Generator is overloaded
Unplug some devices to
reduce load
Short circuit occured in one of
the devices connected
Unplug that device to restore
the stability of a system
Air filter is dirty
Clean the air filter
Repetitions of an engine are
lower than nominal
Contact the service center
Содержание KS 3000