24
20. BATTERY USE
The generator battery is not subject to service. If the generator is not used for a long
time, the battery may fail. To prolong battery life it is recommended to do battery
charging with an external device (not included) every three months.
Please use use protective gloves when working with battery. The battery contains acid
electrolyte, which is dangerous. After contact with skin or face, rinse immediately with
plenty of water and seek for medical advice.
Battery warranted - three months from the date of purchase of the generator.
pic 16
pic 17
Spark
plug
0,60 - 0,80 mm
Electrode
21. STORAGE
Storage room has to be dry and free from dust deposits. Storage room also has to
be locked away from children and animals. It is recommended to store and use the
generator at temperature of -20 to +40
o
С. Avoid direct sunlight, rain on the generator.
When using and storing hybrid generator, gas tank should be kept indoors at
temperatures below +10
o
С. If the temperature is lower, gas will evaporate.
Warning! Generator is to remain ready for operation at all times.
Therefore in case of device malfunctions, they are to be repaired
before dismounting the generator for storage.
Before long-term generator idle time – perform the following actions:
- Generator and engine external parts (especially the cooling radiators) are to be
thoroughly cleaned.
- Carburetor float chamber screw has to be removed and the chamber – drained.
- Remove the spark plug.
- Oil drain screw is to be removed and the oil – drained.
- Pour one teaspoon of motor oil to the cylinder (5-10 ml). After that – pull the starter
cord for a few times, to let the oil equally distribute on the cylinder walls.
- Install the spark plug.
- Pull the starter handle until you feel the resistance. to let the piston relocate to the
upper pressure tact point.
- Smoothly release the starter handle.
- Remove the battery terminals. Grease the battery terminals and connecting
terminals with grease to protect against oxidation.
Before long-term storage of the generator during the engine work
close the fuel valve and let the engine to elaborate gasoline from
carburetor. Wait until engine stops itself.
!
!
IMPORTANT!
!
!
IMPORTANT!
Содержание KS 3000
Страница 29: ......