18
1. Position the air flaps when running on gasoline.
2. Position the air flaps when running on gas.
3. Operating mode.
1
2
3
pic 11
hose
release flap
Place the container with gas only vertically, according to the
instruction manual for gas cylinders. The horizontal placement of gas
cylinders leads to hybrid generator gearbox failure.
!
!
IMPORTANT!
pic 12
pic 13
launch
button
Upon activated ATS system when the electic power from main electric
network passes through the generator to the connected devices, its
accumulator unit is charging. Do not disconnect the battery.
If the power supply from the main network will be stopped, the ATS system will
automatically start the generator so that it begins to supply power to devices
connected to it. When the power supply from the main network is renewed, the
generator system turns off and the voltage to consumers goes from the main
network.
In order to run the generator without ATS mode – do not set the ATS switch to
AUTO mode.
13.3. GENERATOR LAUNCH IN ATS MODE (FOR GENERATORS WITH ATS):
Built-in automatic start system allows controlling the generator switching on and off
in automatic mode. If the main power shuts down, the system will notice that and will
start compensation procedures.
To start the generator engine in ATS mode:
1. Check if the accumulator unit is charged. Oil level is to be sufficient. Also confirm
the fuel tank filling.
2. Connect the power from main power supply to a corresponding inlet at the
generator panel.
3. Set the ATS switch to AUTO position.
4. Set the starting key to “ON” position at the generator panel.
!
!
IMPORTANT!
Содержание KS 3000