21
Such damages are also:
• Damages occurred as a result of using non original spare parts;
• Corrosion damages and other results of improper equipment storage;
• Damages occures as a result of maintanance performance by inexperienced
and unauthorized specialists.
This manual compliance.
Technical maintanance, operation and Könner & Söhnen™ generator storage are
to be performed according to this manual recommendations. Manufacturer
bears no responsibility for damages and losses, caused by incompliance to safety
requirements and technical maintanance rules.
First of all this applies to:
- use of lubricants, gasoline and motor oils, forbidden by the manufacturer;
- device technical alterations;
- equipment operations against its intended use;
- indirect damages, caused by operating faulty equipment;
16. MAINTENANCE SCHEDULE
Node
Ser
vic
e t
ype
First mon
th
or 20 hours
Bef
or
e star
ting
Each mon
th or af
ter
20 w
ork
ing hours
Each 3 mon
ths or
af
ter 50 w
ork
ing hrs
Each 6 mon
ths or
aft
er 100 w
ork
ing hrs
Each y
ear or af
ter
300 w
ork
ing hrs
Motor
oil
Checking
level
V
Changing
V
V
Air
filter
Changing
V
V
filter
V
Sparking
plug
Changing
V
V
Changing
V
Fuel
tank
Checking
level
V
Cleaning
V
Fuel
filter
Cleaning
V
Содержание KS 3000