Nesis III — Installation Manual
13.3
Channels
Figure 58:
An action window example. Channel was already edited hence the
offset option is also shown.
Reset
clears all the channel data and set the channel as not used.
Min/Max
is used to define the sensor limits, required for some functions like
trim and flap.
Offset
is used to slightly adjust the sensor’s zero settings. Not all sensors
support this.
Tank
is used to give additional details for the fuel level sensor.
In order to access the last three options, channel must be first properly set
with the
Edit
command.
13.3.1
Channel Editing
The channel editor window depends on the channel type and also on the
selected function and sensor. Bottom part of the window changes dynamically,
but the first four items are the same for all channels. Figure 59 shows and
example of channel editing window.
Function
A list of functions available for this type of channel is shown on one
of them is selected. The function tells what the channel is measuring.
Sensor
A list of sensors available for the selected channel and selected func-
tion is provided. Select one from the list. This tells Daqu what kind of
signal is to be expected on this channel.
Report time
defines how quickly will Daqu send the measurements on the
CAN bus. This is defined as a time interval between two measurements
being sent. Small value means that measurements are send frequently.
65
©
Kanardia
2018