Nesis III — Installation Manual
10.3
Connection Details
Figure 47:
Home page of the AT1 device. RS-232 data port 3 was not set yet.
Nesis will connect to data port 3. Default protocol for port 3 is Garmin TIS
protocol. This must be changed. At the same time we also recommend using
higher baud rate. In order to change this, select the
Advance Configuration
button and scroll down until the RS-232 data port section. Figure 48 shows
settings we used.
1. Change the
RS-232 data port 3 Output
to FLARM PROTOCOL and
2. change the
RS-232 data port 3 RS-232 Data Rate
to 57600.
3. You can also experiment with
Range
and
Vertical Range
settings, but
default values are OK.
4. Press the
Save
button to activate the changes.
Nesis requires a few seconds to detect new data rate and detect the format.
This procedure is automatic.
Unfortunately, AT1 does not fully implement the Flarm protocol. So Ne-
sis can’t obtain device information. An attempt to access any of the ADS-
51
©