Nesis III — Installation Manual
13.1
Engine Model
Figure 57:
An example window for engine and sensors.
13.1
Engine Model
Engine model shall be selected first. This tells Daqu if this is a classical engine
or it has some kind of ECU (Rotax iS, UL-Power, D-Motor, . . . ). For some
engines it also tells which software fuel flow calculation models shall be used
(It is used only when real fuel flow sensors is not present.)
The
Generic engine
option can be used for any engine any is normally used
with Lycomming, Continental . . .
Some ECU base engines provide fuel flow information. For all others, a fuel
flow sensor is recommended even where such a software fuel flow model exists.
13.2
Switch Function
This option is only available, when miniDaqu is connected to the CAN bus.
Standard Daqu does not have this possibility.
The miniDaqu EMS box has one auxiliary digital port, which is acting as a
switch. This switch function as:
Not used
the switch is not in use.
ECU start
can be used in conjunction with Rotax iS engine only. It is used
to automatically engage/disengage the start button switch. This can
be useful in engine start sequence.
63
©
Kanardia
2018