Nesis III — Installation Manual
3. Power Installation
1
2
3
4
Figure 8:
Example of spacer stud fixed with epoxy:
1
O
– spacer stud,
2
O
– panel surface sanded with 60 grid sandpaper,
3
O
– spacer stud
sanded with dremel tool, coat removed,
4
O
– spacer stud fixed with
epoxy mixed with cotton flox.
3
Power Installation
Nesis power input requirements are compatible with 12 and 24 V aircraft
power systems. Nesis accepts 10 – 30 V range.
The supplied power cable have two unterminated wires. The red wire must be
connected to the power (+12V or +24V) terminal. The blue wire connects to
the ground terminal. The other side of the power cable has a plastic connector.
This connector has a hook next to the red cable. Insert the connector into
Nesis at the back. The notch and the hook must match – they prevent wrong
cable orientation, see Figure 9.
When a slave Nesis is also connected to the system, it is powered with its own
power cable.
1
2
Figure 9:
Left: The power conector on cable. Right: Power connector on Nesis
back.
1
O
– hook on the power cable connector,
2
O
– notch on Nesis
back.
The cable side of power connector
1
O
consists of the following parts:
plastic part with a hook . . . W¨
urth Elektronik, PN 649 002 113 322,
18
©
Kanardia
2018