7.4
Configuration
miniDaqu — Manual
Table 6:
Connection table for serial RS-232 bus.
DB9-ECU
Daqu Function
ECU
Pin 2
RS232 RX
RS232 TX
Pin 3
RS232 TX
RS232 RX (connection not required)
Pin 1
GND
N/C
7.4
Configuration
When configuring Daqu, correct Engine model must be selected. An example
of configuration dialog is illustrated on Figure 22.
Figure 22:
An example ULPower engine selection.
Select one of the following options:
ULPower RS-232
when ECU is connected using RS-232 serial connection.
ULPower CAN 125 kb/s
when ECU is connected using CAN. The communi-
cation speed is 125 kb/s. This speed was used ECUs delivered until
1.11.2018. Please check your ECU.
ULPower CAN 500 kb/s
when ECU is connected using CAN. The speed 500
kb/s is used in latest ECUs. Please check your ECU.
When additional Daqu channels are used, they must be properly configured.
A function selected by Daqu channel will override same function provided by
ECU or AUX.
8
MWfly Engines
CAUTION: This section is preliminary!