7.3
ECU RS-232 Connection
Table 4:
Connection table for CAN bus.
DB9-ECU
Function
ECU
Pin 6
CAN A Low
ECU1 CAN Low
Pin 7
CAN A High
ECU1 CAN High
Pin 8
CAN B Low
connect pins 8 and 4
Pin 4
CAN B High
with
120 Ω
resistor
Pin 1
GND
N/C
7.2.2
Two ECUs
When two ECUs are used, they are already terminated and no additional
resistor is needed. Table 5 summarizes connections.
Table 5:
Connection table for CAN bus.
DB9-ECU
Function
Dual ECU
Pin 6
CAN A Low
ECU1 CAN Low
Pin 7
CAN A High
ECU1 CAN High
Pin 8
CAN B Low
ECU2 CAN Low
Pin 4
CAN B High
ECU2 CAN High
Pin 1
GND
N/C
7.3
ECU RS-232 Connection
The serial port interface can be connected to only one ECU. Daqu receives
data stream from ECU, decodes data and send it over Kanardia CAN bus
protocol. Please refer to Table 6 for connecting ULPower ECU to Daqu via
serial protocol. Please note that GND is usually not connected to prevent
ground-loops. In this case the engine and Daqu must be connected to the
common aircraft ground. But if the GND line is also connected, there should
be no harm.
ECU does not listen to Daqu TX and nothing is sent from Daqu anyway. So
connection of Pin 3 is not required.