ULTRAFLOW® 54/34
Kamstrup A/S · Technical description · 5512-2464_A1_GB_08.2019
7
2
Data
ULTRAFLOW® 54 and ULTRAFLOW® 34
2.1
Electrical data
Supply voltage
3.6 VDC ±0.1 VDC
Battery
(Pulse Transmitter/
Pulse Divider)
3.65 VDC, D-cell lithium
Replacement interval
6 years @ t
BAT
30 °C
With output module (Y=3)
Mains supply
(Pulse Transmitter/
Pulse Divider)
230 VAC +15/-30 %, 50 Hz
24 VAC ±50 %, 50 Hz
Power consumption,
mains supply
1 W
Backup mains supply
Integral SuperCap eliminates interruptions due to short-term power failures
Cable length,
Flow sensor
Pulse Transmitter/
Pulse Divider
Cable Extender Box
Max 10 m
Depending on calculator. Max 100 m when connected to MULTICAL® (Y = 2)
Depending on calculator. Max 30 m when connected to MULTICAL® 603 or 803
EMC data
Fulfils EN 1434:2015 class C, MID E1 and E2
2.2
Mechanical data
Metrological class
2 or 3
Environmental class
Fulfils EN 1434 class C
Mechanical environment
MID M1 and M2 (M2 only flow sensor type 65-5-XXHX-XXX)
Ambient temperature
5…55 °C
non-condensing, closed location (installation indoors)
Protection class
Flow sensor
Pulse Transmitter/
Pulse Divider
Cable Extender Box
IP65
IP67
IP 65
When properly installed.
See paragraph
Humidity
ULTRAFLOW® 54
ULTRAFLOW® 34
Non-condensing,
93 % RH
Condensing (periodically)
Medium in flow sensor
Water
–
recommended water quality as described in CEN TR 16911 and AGFW FW510
Temperature of medium
ULTRAFLOW® 54
ULTRAFLOW® 34
15…130 °C
2…130 °C or 2…50 °C
At medium temperatures above 90°C, the use of flange
meters is recommended.
At medium temperatures above 90 °C or below the
ambient temperature, the calculator and Pulse
Transmitter/Pulse Divider must not be mounted on the
flow sensor. Instead wall mounting is recommended.
Storage and transport
temperature, empty sensor
-
25…60 °C
Pressure stage
PN16, PS16 and PN25, PS25