ULTRAFLOW® 54/34
16
Kamstrup A/S · Technical description · 5512-2464_A1_GB_08.2019
4.4.4
Pulse Divider configuration CCC-DD-E-MMM
If ULTRAFLOW® is connected to calculators with different meter factor than the one supplied by ULTRAFLOW®, a Pulse
Divider is used.
Pulse Divider must be configured in accordance with
for ULTRAFLOW® meter factor (CCC), which is unique for
the nominal flow q
p
. In addition, the desired meter factor (DD) and pulse length (E) of the Pulse Divider is determined by
the connected calculator. MMM indicates selection of customer label.
q
p
CCC
[m³/h]
[pulses/l] [l/pulse] Divider
DD
[ms] (E=1) [ms] (E=4) [ms] (E=5) [ms] (E=6)
0.6
116
300
3.9
-
-
-
Default
0.6
1
300
33
-
20
50
100
0.6
2.5
750
63
-
-
-
100
1.5
119
100
3.9
-
-
-
Default
1.5
1
100
33
-
20
50
100
1.5
2.5
250
63
-
-
-
100
1.5
10
1000
34
-
-
-
100
2.5
198
60
3.9
-
-
-
Default
2.5
1
60
33
-
20
50
100
2.5
2.5
150
63
-
-
-
100
2.5
10
600
34
-
-
-
100
3.5
151
50
3.9
-
-
-
Default
3.5
1
50
33
-
20
50
-
3.5
2.5
125
63
-
-
-
100
3.5
10
500
34
-
-
-
100
3.5
25
1250
64
-
-
-
100
6
137
25
3.9
-
-
-
Default
6
1
25
33
-
20
50
-
6
2.5
62.5
63
-
-
-
100
6
10
250
34
-
-
-
100
6
25
625
64
-
-
-
100
10
178
15
3.9
-
-
-
Default
10
1
15
33
-
20
50
-
10
10
150
34
-
-
-
100
10
25
375
64
-
-
-
100
15
120
10
3.9
-
-
-
Default
15
1
10
33
-
20
-
-
15
10
100
34
-
-
50
100
15
25
250
64
-
-
-
100
15
100
1000
35
-
-
-
100
25
179
6
3.9
-
-
-
Default
25
1
6
33
-
20
-
-
25
10
60
34
-
-
50
100
25
25
150
64
-
-
-
100
25
100
600
35
-
-
-
100
Meter factor
Pulse duration
Table 10. Configuration variants of meter factor (DD) and pulse duration (E)
for Pulse Divider for ULTRAFLOW® X4, q
p
0.6…25 m
3
/h.
Based on a q
p
-value, one of the meter factor options for the Pulse Divider is selected from
. The pulse duration
options appear from the same line as the selected meter factor.
Example: For ULTRAFLOW® X4 with q
p
1.5 m
3
/h (100 imp/l, CCC=119), a meter factor of 1 l/pulse (DD=33) for the Pulse
Divider is required. Based on this meter factor, you have the option of pulse durations 20 (E=4), 50 (E=5) or 100 (E=6)
milliseconds.