MULTICAL® 801
Kamstrup A/S · Technical Description · 5512-571_R1_GB _11.2016
45
6.8.2
Average temperatures
MULTICAL
801 currently calculates the average temperatures of inlet and outlet pipes (T1 and T2) in
°
C without
decimals, and the background calculations E8 and E9 (m
3
x T1 and m
3
x T2) are carried out with every energy
calculation (e.g. with every 0.01 m
3
if the meter size is qp 1.5), whereas the display is updated every 24 hours. The
average temperatures are thereby volume weighted and can, therefore, be used for check purposes directly.
Type of registration
Average
Yearly data
Monthly data
Year-to-date average (since latest target date)
•
•
Month-to-date average (since latest target date)
•
•
Year-to-date average for T1
(Current date with a stipulated line under year or
month is shown immediately BEFORE this reading)
6.8.3
Preprogrammed temperatures
Temperatures T3 and T4 can be programmed into the calculator’s memory, whereby these temperatures can be
used for energy calculation with fixed temperature reference, as used in the calculations of the energy types E4, E5,
E6 and E7 (see application drawings in paragraph 6.2)
The temperatures can be entered from the factory or by means of METERTOOL, in the range 0.01…180
°
C, after
installation.