Technical Description 

 

 

 

 

 

 

 

 

 

MULTICAL® 801

 

Содержание MULTICAL 801

Страница 1: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com Technical Description MULTICAL 801...

Страница 2: ...MULTICAL 801 2 Kamstrup A S Technical Description 5512 571_R1_GB_11_2016...

Страница 3: ...e division 27 3 7 MN Configuration of leak limits 28 3 8 Data for configuration 29 4 Dimensioned sketches 30 5 Installation 31 5 1 Mounting in inlet or outlet pipe 31 5 2 EMC conditions 32 5 3 Climati...

Страница 4: ...98A 83 10 Power supply 84 10 1 Built in battery backup 84 10 2 230 VAC supply 85 10 3 24 VAC supply 85 For MULTICAL 801 with both analog outputs and high power communication we recommend a stronger t...

Страница 5: ...iption 5512 571_R1_GB _11 2016 5 15 Approvals 117 15 1 Type approvals 117 15 2 The Measuring Instrument Directive 117 16 Troubleshooting 118 17 Environmental declaration 119 17 1 Disposal 119 17 2 Tra...

Страница 6: ...importance to flexibility through programmable functions and plug in modules in order to secure optimum use in a wide range of applications In addition the construction makes it possible to update pre...

Страница 7: ...sensors Type 67 F and 67 K Pt100 EN 60 751 4 wire connection Type 67 G and 67 L Pt500 EN 60 751 4 wire connection Compatible flow meter types ULTRAFLOW Electronic meters with active or passive pulse o...

Страница 8: ...attery backup of energy measurement incl ULTRAFLOW Data communication Standard KMP protocol with CRC16 used for optical communication as well as base modules Power of temperature sensors 10 W RMS Main...

Страница 9: ...et range 0 01 180 00 C 0 01 180 00 C 0 01 180 00 C 0 01 180 00 C Type 67 G and 67 L 4 W Pt100 Measuring range 0 00 185 00 C 0 00 185 00 C 0 00 185 00 C N A Preset range 0 01 180 00 C 0 01 180 00 C 0 0...

Страница 10: ...V 680 k pull up to 3 6 V Pulse ON 0 4 V i 30 ms 0 4 V i 30 ms Pulse OFF 2 5 V i 30 ms 2 5 V i 30 ms Pulse frequency 1 Hz 3 Hz Electrical isolation No No Max cable length 25 m 25 m Requirements to ext...

Страница 11: ...MULTICAL 801 Kamstrup A S Technical Description 5512 571_R1_GB _11 2016 11 2 5 Accuracy Figure 1 MULTICAL 801 typical accuracy compared to EN 1434...

Страница 12: ...changed reconfigured after installation Please note that the points marked Total prog cannot be changed without breaking the verification seal This means that the change must be carried out by an accr...

Страница 13: ...MS 15 min Individual key 31 Wireless M Bus Mode C1 Alt reg Individual key pulse inputs 35 Wireless M Bus Mode C1 Fixed Network Individual key 38 ZigBee 2 4 GHz int ant pulse inputs 60 Metasys N2 RS485...

Страница 14: ...ich cannot be changed without breaking the verification seal determines the meter s legal parameters This means that the change must be made by an accredited laboratory The A code states whether flow...

Страница 15: ...nical Description 5512 571_R1_GB _11 2016 15 Prog number A B CCC V1 CCC V1 Flow meter position k factor table Inlet at T1 3 Outlet at T2 4 Measuring unit Energy x10 GJ 1 GJ 2 kWh 3 MWh 4 Gcal 5 Flow m...

Страница 16: ...ration frequency 1 Hz CCC 0XX Mechanical meters delivering slow pulses with bounce flow sensor type L Max pulse frequency 1 Hz Max integration frequency 1 Hz Max integration frequency is 1 Hz for all...

Страница 17: ...6 65 X CHAF XXX 1 2 7 8 65 X CHAG XXX 65 X CHAH XXX 65 X CHB CB XXX 438 250 943704 0 3 2 2 0 1 25 6 1 2 7 8 447 1000 2359260 1 0 0 2 3 1 0 150 65 5 FCCN XXX 1 2 7 8 478 1500 1572840 2 1 1 0 1 15 10 65...

Страница 18: ...A7X 65 54 A1X 65 54 A2X 65 54 A3X 1 2 7 8 136 500 471852 0 3 2 2 0 1 50 0 2 5 65 54 A4X 65 54 ADX 1 2 7 8 151 5000 471852 2 1 1 0 1 50 0 3 5 65 54 B1X 65 54 B7X 1 2 7 8 137 2500 943704 2 1 1 0 1 25 0...

Страница 19: ...15 0 10 65 X CJAJ XXX 65 X CJBD XXX 1 2 7 8 N 120 1000 2359260 2 1 1 0 1 10 0 15 65 X CKBE XXX 1 2 7 8 N 179 600 3932100 2 1 1 0 1 6 0 25 65 X CLBG XXX 1 2 7 8 N 120 1000 2359260 2 1 1 0 1 10 0 25 65...

Страница 20: ...0 3 2 2 0 1 50 0 3 5 1 2 7 8 N 138 250 943704 0 3 2 2 0 1 25 0 6 0 10 1 2 7 8 N 183 150 1572840 0 3 2 2 0 1 15 0 10 1 2 7 8 185 100 2359260 0 3 2 2 0 1 10 0 15 1 2 7 8 N 186 500 471852 2 1 1 2 0 5 0...

Страница 21: ...177 2500 943704 1 0 0 2 3 2 5 40 80 DF 40 N Number of decimals in display CCC No Pre counter Flow factor MWh Gcal GJ m tons m h MW l imp Imp l Qp range m h Qs m h Type Flow sensor 201 100 235926 2 1...

Страница 22: ...67 2 1 1 0 1 29 82 2 5 3 5 HM N 128 2424 973292 2 1 1 0 1 24 24 3 5 HM N 129 1854 1272524 2 1 1 0 1 18 54 6 HM N 130 770 3063974 2 1 1 0 1 7 7 10 HM N 131 700 3370371 2 1 1 0 1 7 0 15 HM N 132 365 645...

Страница 23: ...020 4 230400 0 3 2 2 2 0 2 5 0 4 6 L 021 4 230400 2 1 1 1 2 25 0 04 3 60 L 022 4 230400 1 0 0 0 1 250 0 004 30 600 L Current flow indication l h or m h is calculated based on measured duration betwee...

Страница 24: ...A 4 2 Monthly data 3B 3B 2B 3B 1B 1B 3A 4 3 Mass 1 3B 4 4 P1 3C 5 0 Volume V2 4 5 1 Yearly data 5 2 Monthly data 4A 5 3 Mass 2 4B 5 4 P2 4C 6 0 Hour counter 4 4 3 4 2 2 5 7 0 T1 Inlet 5 5 4 5 6 7 1 Ye...

Страница 25: ...ware edition No 10 16H 16H 12H 15H 8H 8H 17H 20 9 Software check sum No 11 16I 16I 12I 15I 8I 8I 17I 20 10 Segment test 16J 16J 12J 15J 8J 8J 17J 20 14 Module type 1 No 30 16K 16K 12K 15K 8K 8K 17K 20...

Страница 26: ...isters TA2 and TA3 which can accumulate heat energy E1 EE 20 accumulates volume parallel with the main register based on the limits programmed for tariff limits TL2 and TL3 Example EE 11 Power tariff...

Страница 27: ...1 m h 100 1 0 vol A vol b m3 000000 0 24 10 m h 24 10 m h 1 10 vol A vol b m3 00000 00 25 5 m h 25 5 m h 2 5 0 vol A vol b m3 00000 00 26 2 5 m h 26 2 5 m h 4 2 5 vol A vol b m3 00000 00 27 1 m h 27 1...

Страница 28: ...M Sensivity of leak search N Constant leakage at no consumption pulse resolution 10 l imp 0 OFF 0 OFF 1 1 0 qp 20 q 1 20 l h 3x10 min 30 min without pulses 2 1 0 qp 10 q 2 10 l h 6x10 min 1 hour with...

Страница 29: ...1 180 C 25 C at DDD 5xx and 6xx T2 prog 0 01 180 C T3 prog 0 01 180 C 5 C T4 prog 0 01 180 C 0 C 0 C YYYY MM DD hh mm ss GMT offset according to country code GMT 12 0 hours 30 min in leaps Data regist...

Страница 30: ...cal Description 5512 571_R1_GB_11_2016 4 Dimensioned sketches Front measurements of MULTICAL 801 Installation measurements of MULTICAL 801 Wallmounted MULTICAL 801 seen from the side Cable unions of M...

Страница 31: ...eters Heat cooling meters Flow sensor position k factor table Inlet at T1 3 Outlet at T2 4 Formula k factor Prog Hot pipe Cold pipe Installation Heat meter E1 V1 T1 T2 k k factor for T1 in Inlet table...

Страница 32: ...es and other installations 5 3 Climatic conditions MULTICAL 801 has been designed and approved for indoor installation in non condensing environments with ambient temperatures from 5 55 C Furthermore...

Страница 33: ...d or simulated water volume in m3 If e g the CCC code 119 is used the calculator has been programmed to receive 100 imp litre If for instance 10 000 pulses are added this corresponds to 10 000 100 100...

Страница 34: ...E6 V2 T3 T4 k T3 Inlet T3 T4 Tap water energy separate 3 6 Display Data Log E7 V2 T1 T3 k T3 Outlet T1 T3 Returned energy or tap from inlet pipe 4 8 Display Data Log E8 m3 x T1 Average temperature in...

Страница 35: ...uring PROG Mass M1 V1 Kmass t1 or Mass M1 V1 Kmass t2 depending on inlet outlet programming Mass M2 V2 Kmass t3 Application no 4 2 heating circuits with joint inlet pipe Heat energy 1 E1 V1 T1 T2 k T2...

Страница 36: ...ed Mass M1 V1 Kmass t1 Mass M2 V2 Kmass t3 Application no 7 Open system with 2 flow meters Forwarded energy E4 V1 T1 T3 k T1 Inlet Returned energy E5 V2 T2 T3 k T2 Inlet E E4 E5 cannot be calculated b...

Страница 37: ...g circuits with joint inlet pipe Cooling energy 1 E4 V1 T1 T3 k T1 Inlet Cooling energy 2 E5 V2 T2 T3 k T2 Inlet Application no 10 Two stage boiler system with 1 flow meter Boiler energy B E3 V1 T2 T1...

Страница 38: ...3 tR E9 is accumulated by the product of m3 tR Resolution of E8 and E9 E8 and E9 depend on the resolution of volume m3 Volume resolution Resolution of E8 and E9 0000 001 m3 m3 C 10 00000 01 m3 m3 C 00...

Страница 39: ...heat exchanger will provide the necessary electric coupling Electric coupling Inlet and outlet pipes are closely electrically coupled No welded joints occur In installations where the electric coupli...

Страница 40: ...energy E3 is measured at negative temperature difference T2 T1 Temperature sensor T1 with a red type sign must be installed in the hydraulic inlet pipe whereas T2 is installed in the outlet pipe The t...

Страница 41: ...q 88 x 235926 65535 316 8 which is displayed as 316 l h Current water flow in V1 Slow volume pulses CCC 0XX The current water flow of slow volume pulses typically from flow meters with reed contact is...

Страница 42: ...ation based on the following formula P q T1 T2 x k kW or MW k being the heat coefficient of water which is currently calculated by MULTICAL 801 according to EN 1434 2007 Example Current water flow q 3...

Страница 43: ...number of current flow or power measurements respectively The average period used for all calculations can be selected in the interval 1 1440 min in 1 min leaps 1 440 min 24 hours Average period and...

Страница 44: ...gy calculation not at shorter intervals than 10 s however The temperature range of the measuring circuit is 0 00 C 185 00 C For disconnected temperature sensor 200 00 C is shown and for short circuite...

Страница 45: ...purposes directly Type of registration Average Yearly data Monthly data Year to date average since latest target date Month to date average since latest target date Year to date average for T1 Curren...

Страница 46: ...ergy is displayed Activating the pushbuttons the display reacts at once by calling up other indications The display automatically returns to energy indication 4 minutes after the latest activation of...

Страница 47: ...p A S Technical Description 5512 571_R1_GB _11 2016 47 Heat energy E1 in MWh Yearly data date of LOG1 latest yearly reading Yearly data value of LOG1 latest yearly reading Monthly data date of LOG1 la...

Страница 48: ...umber of secondary readings in connection with yearly and monthly data has been determined under the DDD code In the absence of other information with the order readings will consist of 2 yearly data...

Страница 49: ...1 1 1 Yearly data 1 2 Monthly data 2 0 Cooling energy E3 1 2 1 Yearly data 2 2 Monthly data 3 X Other energy types 3 1 E2 3 2 E4 3 3 E5 3 4 E6 3 5 E7 3 6 E8 m3 tf 3 7 E9 m3 tr 4 0 Volume V1 1 1 4 1 Ye...

Страница 50: ...o No 1 2 20 1 Date 20 2 Hour 20 3 Target date 20 4 Serial no No 3 20 5 Prog A B CCC CCC No 4 20 6 Config 1 DDD EE No 5 20 7 Config 2 FF GG M N No 6 20 8 Software edition No 10 20 9 Software check sum...

Страница 51: ...ppear in the information field Example 2 Current information code Activating the top primary pushbutton several times the current information code is displayed Example 3 Info event counter shows how m...

Страница 52: ...k air After reset and 24 hours at 00 00 16384 Flow meter V1 wrong flow direction After reset and 24 hours at 00 00 32768 Flow meter V2 wrong flow direction After reset and 24 hours at 00 00 If several...

Страница 53: ...fo code info in display Registration in info daily monthly or yearly logger Counting of Info event 1 Yes Yes With each main power On Off 4 8 32 Yes Yes When Info 4 8 32 is set or removed Max 1 per tem...

Страница 54: ...sidered legal billing register no matter the selected tariff function Tariff conditions TL2 and TL3 are monitored with each integration If the tariff conditions are fulfilled consumed heat energy is a...

Страница 55: ...ERTOOL EE 11Power controlled tariff If the current power exceeds TL2 but is lower than or equal to TL3 heat energy is counted in TA2 parallel to the main register If the current power exceeds TL3 heat...

Страница 56: ...3 parallel to the main register T1 TL2 Accumulation in main register only TL3 TL2 TL3 P TL2 Accumulation in TA2 and main register T1 TL3 Accumulation in TA3 and main register Setting up data TL3 must...

Страница 57: ...sumption TA2 accumulates the volume consumed together with E1 heat energy and TA3 accumulates the volume consumed together with E3 cooling energy T1 T2 Volume is accumulated in TA2 and V1 TL2 and TL3...

Страница 58: ...ogger Daily logger Prog logger Date YY MM DD Year month and day for logging time Clock hh mm ss Time Log Info Status quality stamping of log record E1 E1 V1 T1 T2 k Heat energy E2 E2 V2 T1 T2 k Heat e...

Страница 59: ...ontinuous maximum water flow and permanent 75 K may cause overflow in the daily data logger at CCC 010 011 012 013 150 202 205 206 With these combinations we recommend you to use the built in Prog dat...

Страница 60: ...nge corresponding to 300 l h for a single family house is registered an alarm will be sent within 120 s via remote communication Small leaks from 15 kgs h and upwards for qp 1 5 m3 h are monitored on...

Страница 61: ...t heating spirals of tap water tanks or other untightnesses will cause pulses to be received from the cold water meter 24 hours a day If MULTICAL 801 does not register e g at least one continuous hour...

Страница 62: ...must not involve increased risk of erroneous closing which may lead to frost burst Due to this fact the stability and reliability of the complete system must make 12 years operation without further m...

Страница 63: ...data loggers info loggers max min logger without resetting the legal registers can only be carried out by means of METERTOOL See paragraph 14 for further information 6 14 3 Reset of all registers tot...

Страница 64: ...C with METERTOOL if correct time is important for the application in question 6 15 SMS commands MULTICAL 801 can be read by means of an SMS In order to do so a GSM module fitted with a SIM card must b...

Страница 65: ...yntax READ_HEAT_METER Return reply error NO ANSWER Example of SMS command READ_HEAT_METER Example of correct reply 12 067Gj 120 0kW 6930 Hours Meter No 6055524 SIGNAL for reading the signal strength S...

Страница 66: ...or FET output V1 is connected to terminals 10 and 11 V2 is connected to terminals 69 and 11 Terminal 9 is not used in this application The leak current of transistor or FET output must not exceed 1 A...

Страница 67: ...ulses from the flow meter will be transferred to the calculator However data communication between the calculator and the flow meter is disabled In order to avoid erroneous info codes it is therefore...

Страница 68: ...nd calculator Figure 5 Auxiliary voltage from terminals 97A and 98A is added to the passive contact output on terminals 10A and 11A before the signal is connected to the galvanically separated flow se...

Страница 69: ...ty E2 V2 T1 T2 k E1 V1 T1 T2 k Changed polarity E2 V2 T1 T2 k E3 V1 T2 T1 k Figure 8 The active pulse output is direct connected to the galvanically separated flow sensor input This permits a cable le...

Страница 70: ...assive contact output on terminals 56 and 57 is direct connected to the not galvanically separated flow sensor input This permits a cable length of max 10 20 m between flow sensor and calculator Figur...

Страница 71: ...This permits a cable length of up to 100 m between flow sensor and calculator Heat energy Cooling energy Same polarity E2 V2 T1 T2 k E1 V1 T1 T2 k Changed polarity E2 V2 T1 T2 k E3 V1 T2 T1 k Figure...

Страница 72: ...ay CCC No Pre counter Flow factor MWh Gcal GJ m ton m h MW l imp Imp l Qp range m h Qs m h Type Flow sensor 201 100 235926 2 1 1 1 2 1 1 10 100 75 FUS380 DN50 65 N 202 40 589815 2 1 1 1 2 2 5 0 4 40 2...

Страница 73: ...order information or is configured by means of METERTOOL See paragraph 3 6 concerning configuration of VA FF codes and VB GG codes MULTICAL 801 registers the accumulated consumption of the meters con...

Страница 74: ...pulse and a max flow of 10 m3 h The meter connected to VA has meter no 75420145 which is saved in the internal memory of MULTICAL 801 by means of METERTOOL Accumulated register of VA Input A Meter no...

Страница 75: ...115 155 40 115 541 115 927 116 313 116 699 117 085 117 470 117 856 118 241 118 627 119 012 50 119 397 119 782 120 167 120 552 120 936 121 321 121 705 122 090 122 474 122 858 60 123 242 123 626 124 00...

Страница 76: ...100 692 528 694 424 696 319 698 214 700 108 702 002 703 896 705 788 707 680 709 572 110 711 463 713 353 715 243 717 132 719 021 720 909 722 796 724 683 726 569 728 455 120 730 340 732 225 734 109 735...

Страница 77: ...nnected to the use of 2 wire sensor sets according to EN 1434 2 appear from the table below Kamstrup supply Pt500 sensor sets with up to 10 m cable 2 x 0 25 mm2 Cable cross section mm2 Pt100 sensors P...

Страница 78: ...MULTICAL 801 and the screw joint for the 4 wire sensor The isolation material cover of the cable ought to be selected based on the maximum temperature in the installation PVC cables are normally used...

Страница 79: ...8 mm Sensor pockets are available with R conical connection in stainless steel i lengths of 65 90 and 140 mm The sensor construction with separate immersion pipe permits replacement of sensors without...

Страница 80: ...re the sensor element is placed Furthermore it can be direct mounted in many flow sensor types which reduces the installation costs Figure 18 Figure 19 Figure 20 The sensor can be mounted in special T...

Страница 81: ...V 9 2 Analog outputs 80 87 MULTICAL 801 is available with 4 analog outputs The outputs are active 0 20 mA or 4 20 mA can be loaded with 0 500 and are optoisolated in relation to the supply The 4 analo...

Страница 82: ...232 level is possible via data cable type 66 99 106 Adaption to USB is possible via data cable 66 99 098 The data connection uses the KMP protocol Please contact Kamstrup for further details on the K...

Страница 83: ...s based on an unstabilized power supply This means that the output voltage varies depending on load The output current must not exceed 50 mA and the nominal output current is 35 mA The auxiliary suppl...

Страница 84: ...The type number of the backup battery is 66 99 619 2xA lithium battery with plug The lifetime of the backup partly depends on how long MULTICAL 801 remains without mains supply and partly on the temp...

Страница 85: ...disconnect the 230 VAC module whereas an authorized electrician must carry out the fixed 230 V installation into the meter panel 10 3 24 VAC supply Includes a double chamber safety transformer which f...

Страница 86: ...than 3 W without analog outputs or lower than 9 W with analog outputs for the complete meter incl 230 24 V transformer Note The safery transformer 6699 403 is suitable for MULTICAL 801 either with ana...

Страница 87: ...the branch conductor is used no on off switch or separate overcurrent protection in either primary or secondary circuit is required provided that the following conditions are fulfilled The safety tra...

Страница 88: ...gistre P M Bus module with MCIII data package Q M Bus V RadioRouter W LonWorks FTT 10A Y GSM GPRS GSM6H Z 3G GSM GPRS GSM8H U Ethernet IP modul IP201 T Module 1 VA and VB are available in module posit...

Страница 89: ...MULTICAL 801 Kamstrup A S Technical Description 5512 571_R1_GB _11 2016 89...

Страница 90: ...ulse inputs OK OK OK OK OK OK OK 67 00 67 Modbus RTU pulse inputs OK OK OK OK OK OK OK 67 00 84 High Power Radio Router pulse input N A OK N A N A OK N A OK 11 1 2 Options of external communication un...

Страница 91: ...emanding frequencees The module is available with internal antenna as well as connection for external antenna The radio module is prepared to form part of a Kamstrup radio network the read data being...

Страница 92: ...nstructions 5512 1105 GB 11 1 7 M Bus module with alternative registers pulse inputs 67 00 27 670P PCB 5550 997 The M Bus module is supplied via the M Bus network and is independent of the meter s own...

Страница 93: ...2 and the module uses one way communication data being automatically sent from the meter after installation every 15 minutes from module 67 00 31 The T1 OMS module supports individual encryption and...

Страница 94: ...hnson Controls is a widespread and established field bus protocol used within building automation The N2 module for MULTICAL ensures simple integration from Kamstrup s heat and cooling meters to N2 Op...

Страница 95: ...MS TP module appear from data sheet 5810 1055 GB version 11 1 16 Modbus RS485 RTU Slave Module with 2 pulse inputs VA VB 67 00 67 PCB 5550 1277 The Modbus base module for MULTICAL ensures simple integ...

Страница 96: ...oftware and MULTICAL 801 and is used for data reading The module supports both dynamic and static addressing This is specified in the order or selected during subsequent configuration The module has n...

Страница 97: ...via METERTOOL All other configurations are made via LonWorks M Bus module with alternative registers pulse inputs 27 P Pulse values of VA and VB are changed via METERTOOL Primary and secondary M Bus a...

Страница 98: ...ption 5512 571_R1_GB_11_2016 Data modules are retrofitted by placing the module in the PCB holder in the left side of the meter and clicking on the module Insert module Module and meter are electrical...

Страница 99: ...ormity Software checksum based on CRC16 is available via data communication and in the display Integrity and authenticity of data All data parameters include type measuring unit scaling factor and CRC...

Страница 100: ...1DATE YEAR Date of this year s min 126 MIN FLOW1 YEAR This year s min value 127 MAX POWER1DATE YEAR Date of this month s max 128 MAX POWER1 YEAR This year s max value 129 MIN POWER1DATE YEAR Date of t...

Страница 101: ...rotocol Utilities and other relevant companies who want to develop their own communication driver for the KMP protocol can order a demonstration program in C net based as well as a detailed protocol d...

Страница 102: ...is activated The above display example showing 345 4 Wh corresponds to the amount of energy accumulated at inlet 43 00 C and outlet 40 00 C as well as a return volume of 0 1 m3 The high resolution en...

Страница 103: ...olution as the high resolution register of the display see section 12 1 The pulse interface must be voltage supplied on terminals 97 98 from en external supply with 5 30 VDC and the current consumptio...

Страница 104: ...ue energy calculation During test and verification the heat meter s energy calculation is compared to the true energy calculated according to the formula of EN 1434 1 2004 or OIML R75 2002 An energy c...

Страница 105: ...ion equipment Item no 66 99 371 Verification of 67 G L 4 W Pt500 and total partial reconfiguration Data cable w USB Item no 66 99 098 Total partial reconfiguration Optical eye USB Item no 66 99 099 Pa...

Страница 106: ...724 Before running the program connect your optical read out head to your computer and place the read out head resting on the two plastic studs intended for this purpose in the lower right hand corner...

Страница 107: ...ow change of coding which is important to energy calculation e g Type No and Prog No By means of Total programming it is possible to change the remaining values too Programming is only possible if the...

Страница 108: ...missing communication In MULTICAL 801 and ULTRAFLOW 14 cooling meter communication is supported using Pulse Transmitter type 66 99 618 Having read out the current Info code setup Get the below mention...

Страница 109: ...register values of the two extra pulse inputs for water and electricity meters 14 2 11 Print Label Advanced Mode Initiates printing of meter label 14 2 12 Verification Advanced Mode See paragraph 14 3...

Страница 110: ...program can be updated if a newer revision is available on Kamstrup s FTP server Update database In this menu the METERTOOL database can be updated if a newer revision is available on Kamstrup s FTP...

Страница 111: ...evision numbers for the entire HCW program 14 2 20 Backup Used for exporting importing a backup file of saved verification data 14 2 21 Windows The function makes it possible to change between open di...

Страница 112: ...ed for configuration test and verification In order to carry out verification the programming lock must be closed throughout the verification see paragraph 14 2 2 General information The verification...

Страница 113: ...TERTOOL HCW and the verification equipment is used a number of calibration data must be entered into the menu Verification Unit Settings in METERTOOL HCW Calibration data is electronically included in...

Страница 114: ...ed the result will be displayed If the result can be approved click on Save The result is now saved in the database under the serial number of the calculator You can save several results under one ser...

Страница 115: ...1 counts at optional intervals between 1 and 1440 minutes as well as an optional number of repetitions of the reading between 1 and 9999 times For read out of current counts enter interval 1 and repet...

Страница 116: ...or list form by activating Graph Table toggle function In order to carry out a new data read out you just select a new period and new data registers If the formerly read values have not been saved pre...

Страница 117: ...ort project A530573 has been prepared by DELTA and forms the basis of the MID approval MULTICAL 801 has a national Danish cooling approval TS 27 02 006 according to BEK 1178 based on EN1434 2007 15 2...

Страница 118: ...he display Check the error indicated by the info code see paragraph 6 8 If info 000 Check that the flow direction matches the arrow on the flow sensor If info 004 008 or 012 Check the temperature sens...

Страница 119: ...yl chloride 2 pcs A cell lithium 0 96 g lithium each Approved deposit of lithium cells PCBs in MULTICAL 801 LC display is removed Coppered epoxy laminate soldered on components PCB scrap for metal rec...

Страница 120: ...S Technical Description 5512 571_R1_GB_11_2016 18 Documents Danish English German Technical Description 5512 570 5512 571 5512 572 Data sheet 5810 624 5810 625 5810 626 Installation and User s guide...

Страница 121: ...MULTICAL 801 Kamstrup A S Technical Description 5512 571_R1_GB _11 2016 121...