6  Retroitting modules

Both top modules and base modules for MULTICAL® 62 can be supplied separately for retroitting. 
The modules are conigured and ready for installation from the factory. Some of the modules 
require individual coniguration after installation, which is possible by means of METERTOOL.

Top module

Possible coniguration after installation

Data hourly data logger

5

Clock adjustment.

RTC + M-Bus

7

Clock adjustment.
Primary and secondary M-Bus addresses can be 
changed via METERTOOL or M-Bus. Furthermore, 
monthly logger data can be selected instead of yearly 
logger data via M-bus.

RTC + pulse output for CV + prog. data logger

B

Clock adjustment.
Coniguration of pulse outputs.

2 pulse outputs for CE and CV

C

Connection and pulse value are changed via 
METERTOOL.

Base module

Data + pulse inputs

10

Pulse values of VA and VB are changed via 
METERTOOL.

M-Bus + pulse inputs 

20

Pulse values of VA and VB are changed via 
METERTOOL.
Primary and secondary M-Bus addresses can be 
changed via METERTOOL or M-Bus. Furthermore, 
monthly logger data can be selected instead of yearly 
logger data via M-bus.

Radio pulse inputs

21

Pulse values of VA and VB are changed via 
METERTOOL.

Prog. data RTC + 4…20 mA  
pulse inputs

22

Clock adjustment.
Pulse values of VA and VB are changed via 
METERTOOL.

0/4…20 mA outputs

23

Conig data must be programmed into the calcu-
lator by means of METERTOOL when retroitting. 
Furthermore, all parameters can be changed via 
METERTOOL.

LonWorks, pulse inputs

24

Pulse values of VA and VB are changed via 
METERTOOL. All other conigurations are made via 
LonWorks.

Radio + pulse inputs (integral antenna)

25

Pulse values of VA and VB are changed via 
METERTOOL.

Radio + pulse inputs (connection for external 
antenna)

26

Pulse values of VA and VB are changed via 
METERTOOL.

Содержание MULTICAL 62

Страница 1: ...Installation and User Guide MULTICAL 62 Water meter ...

Страница 2: ...alling the meter In case of incorrect mounting Kamstrup s guarantee obligations no longer apply MULTICAL 62 is a cold water meter 0 1 50 C or 0 1 30 C and a hot water meter 0 1 90 C consisting of a low sensor and a calculator The low sensor electronics are placed in the calcula tor s connecting base whereas the calculator top is a display unit The low sensor is connected to the calculator by means...

Страница 3: ...ater meter 0 1 50 C Hot water meter 0 1 90 C Pressure stage Threaded meters PN16 Flange meters PN25 Mechanical environment M1 MID Fixed installation with minimum vibra tion Electromagnetic environment E1 MID Housing and light industry The meter s control cable must be drawn at min 25 cm distance from other installations Climatic environment 5 C 55 C Must be installed indoors and in environments wi...

Страница 4: ...sor Threaded meters are mounted by means of couplings You must make sure that the threaded lengths of the couplings do not prevent proper tightening of sealing surfaces and that PN10 cou plings are used PN16 couplings gaskets can be used Using strainer and or nonreturn valve the enclosed thicker PE polyethylene gaskets must be used in order to avoid damaging strainer or nonreturn valve Strainer no...

Страница 5: ...lator MULTICAL 62 must be mounted on a wall Use the itting as a template to mark and drill two 6 mm holes in the wall If the low sensor is mounted with the plastic housing pointing downwards the calculator ought to be mounted using an angle itting type no 3026 252 to be ordered separately The cable must be mounted minimum 25 cm from other electric installations Do not forget to seal the calculator...

Страница 6: ...e of the battery approx 3 65 V Therefore it is not possible to determine the remaining capacity by measuring the voltage The battery cannot and must not be charged and must not be short circuited Used batteries must be handed in for approved destruction e g at Kamstrup A S 3 2 Supply modules The modules are protection class II and are connected via a two wire cable without earth through the cable ...

Страница 7: ...low 5 1 Base modules 5 1 1 Data pulse inputs type 67 00 10 The data terminals are used for connection of e g a PC The signal is passive and galvanically separated by means of optocouplers Conver sion into RS232 level requires connection of data cable 66 99 106 D Sub 9F or 66 99 098 USB with the following connections 62 Brown DAT 63 White REQ 64 Green GND The pulse inputs can be used for connection...

Страница 8: ...d router functions The RadioRouter module must be used with mains supply 5 1 4 Prog data logger RTC 4 20 mA inputs pulse inputs type 67 00 22 The module has connection possibility for two pressure transmitters on terminals 57 58 and 59 and can be adjusted for current reading or pressure ranges of 6 10 or 16 bar The module is prepared for remote reading data from meter module being transferred to t...

Страница 9: ...meter and is powered by the meter s supply The module operates within the 2 4 GHz area and is ZigBee Smart Energy certiied The certiication secures that the meter can form part of other ZigBee networks e g reading several meter types from different meter suppliers To be able to offer a compact solution the module uses an internal antenna 5 1 9 Metasys N2 RS485 N2 RS485 2 pulse inputs type 67 00 62...

Страница 10: ...odule appear from data sheet 5810 1253 GB version 5 1 13 GSM GPRS module GSM6H type 602 00 80 The GSM GPRS module functions as transparent communication path between reading software and MULTICAL 62 and is used for data reading The module includes an external dual band GSM antenna which must be used The module itself includes a number of light emitting diodes indicat ing the signal level which are...

Страница 11: ...tems e g USB Meter Reader and MULTITERM Pro The RadioRouter module is available for operation in both licence free and licence demanding frequences permitting a transmitting strength of up to 500 mW The module is by default itted with internal antenna connection for external antenna and two extra pulse inputs The High Power RadioRouter module 602 00 84 must be used together with the High Power mai...

Страница 12: ...or CV prog data logger The RTC and pulse output functions of this top module are identical with the functions described for top module 67 08 The top module is prepared for use in a Kamstrup radio network together with the Radi oRouter base module 67 00 21 000 3xx read data being transferred to the system software via the network unit RF Concentrator 5 2 4 Type 602 0C 2 pulse outputs for CE and CV ...

Страница 13: ...METERTOOL Base module Data pulse inputs 10 Pulse values of VA and VB are changed via METERTOOL M Bus pulse inputs 20 Pulse values of VA and VB are changed via METERTOOL Primary and secondary M Bus addresses can be changed via METERTOOL or M Bus Furthermore monthly logger data can be selected instead of yearly logger data via M bus RadioRouter pulse inputs 21 Pulse values of VA and VB are changed v...

Страница 14: ... VB are changed via METERTOOL ZigBee 2 4 GHz internal antenna pulse inputs 60 Pulse values of VA and VB are changed via METERTOOL Metasys N2 RS485 pulse inputs 62 Pulse values of VA and VB are changed via METERTOOL SIOX module Auto detect baud rate 64 The baud rate can be set via SIOX TOOL BACnet MS TP 2 pulse inputs 66 Pulse values of VA and VB are changed via METERTOOL Modbus RTU pulse inputs 67...

Страница 15: ...rregularities 1 Supply voltage has been interrupted 16 Flow sensor V1 communication error After reset e g cover off and on as well as automatically after max 24 hours at 00 00 64 Leak in water installation The Water has not been stagnant in the meter for minimum one continuous hour during the latest 24 hours This can be a sign of a leaky faucet or toilet cistern 24 hours 2048 Flow meter V1 wrong p...

Страница 16: ...sal for correction The display value is not updated Power supply missing Change battery or check mains supply No display function empty display Power supply missing Change battery or check mains supply Is there 3 6 VDC on terminals 60 and 61 If INFO 1 Supply voltage has been interrupted The info code is corrected automatically No accumulation of volume m3 Read INFO in the display Check the error i...

Страница 17: ... displayed with the rightmost digit lashing The value of the lashing digit can be changed by pressing the sub key The digit is increased by one each time the key is pressed and passing 9 you start from 0 Pressing the main key you go to the next digit from right to left The active digit lashes and this digit can now be changed by pressing the sub key You go to the irst digit on the right by means o...

Страница 18: ...18 Kamstrup A S 55121068_B3_GB_03 2015 MULTICAL 62 Water meter ...

Страница 19: ...te of min low last month Value of min low last month Followed by the values of min low for the last 12 month Number of hours with errors Reading of number of INFO code events The data logger shows the date and then the INFO codes of the latest 36 events The up to eight most signiicant digits of the customer number The eight least signiicant digits of the customer number In this example the custome...

Страница 20: ...rmation Codes MULTICAL 62 constantly monitors a number of important functions If there is a serious error in measuring system or installation a lashing INFO will appear in the display until the error has been corrected The INFO ield lashes as long as the error exists no matter which reading you choose The INFO ield automatically disappears when the reason for the error has been removed Info code t...

Отзывы: