11
Kamstrup A/S • 55121068_B3_GB_03.2015
MULTICAL® 62 • Water meter
5.1.15 Ethernet/IP module (IP201), type 602-00-82
The IP module functions as transparent communication between reading software and
MULTICAL® 62 and is used for data reading. The Module supports both dynamic and static address-
ing. This is speciied in the order or selected during subsequent coniguration. The module has
no built-in security and must, therefore, always be used in connection with a irewall or NAT. The
Ethernet/IP module must be used together with high-power mains supply (230 VAC: 602-00-00-3
and 24 VAC: 602-00-00-4).
5.1.16 High-Power Radio 2 pulse inputs (VA, VB), type 602-00-84
The High-Power RadioRouter module has built-in router functionality and is thus optimized to form
part of a Kamstrup radio network, the read data being automatically transferred to system soft-
ware via the network unit RF Concentrator. Furthermore, the module can be read by Kamstrup’s
hand-held reading systems, e.g. USB Meter Reader and MULTITERM Pro.
The RadioRouter module is available for operation in both licence-free and licence demanding
frequences permitting a transmitting strength of up to 500 mW. The module is by default itted
with internal antenna, connection for external antenna, and two extra pulse inputs. The High Power
RadioRouter module (602-00-84) must be used together with the High Power mains supply
(230 VAC: 602-00-00-3 and 24 VAC: 602-00-00-4).
5.2 Top modules
5.2.1
Type 67-05: RTC + data hourly
data logger
The module has a galvanically separated data
port which functions with the KMP protocol.
The data output can be used for e.g. connec-
tion of external communication units or other
hardwired data communication which it is not
expedient to carry out via the optical communi-
cation on the meter’s front.
62: DATA (brown) – 63:REQ (white) – 64: GND
(green). Use data cable type 66-99-106 with
9-pole D-sub or type 66-99-098 with USB
connector.
Furthermore, the module includes an hourly
data logger.
Only current and accumulated data can be
read. Hourly/daily/monthly/yearly data loggers
cannot be read through the data port of top
module 67-05.
DAT
REQ
GND
GND