MULTICAL®
403
54
Kamstrup
A/S
∙
Technical
description
∙
5512
‐
1689_B1_GB_03.2017
6
Display
MULTICAL®
403
has
a
bright
and
clear
display
including
7
or
8
digits
depending
on
configuration
as
well
as
a
number
of
symbols
for
measuring
units,
info,
inlet
and
outlet,
radio
on/off
etc.
The
display
is
switched
on
by
pressing
either
the
primary
or
the
secondary
key
on
the
meter’s
front.
Depending
on
the
selected
integration
mode
(L
‐
code)
the
display
either
switches
off
8
min.
after
the
latest
activation
of
a
key
or
remains
switched
on.
Thus
the
selected
integration
mode
influences
the
meter’s
battery
lifetime.
Read
more
about
battery
lifetime
in
paragraph
10.4
and
more
about
the
meter’s
integration
modes
in
paragraph
3.2.7.
1
The
meter
is
configured
as
inlet
or
outlet
meter
6
Date,
time
and
address
2
Flashes
at
active
info
code
7
Heart
beat
indication
shows
that
both
meter
and
display
are
active
3
Historical
readings
8
”OK”
is
displayed
when
a
changed
value
has
been
saved
4
Tariff
registers/tariff
limits
9
The
meter’s
radio
communication
is
switched
on
or
off
5
Measuring
unit
The
meter
uses
four
different
display
loops.
The
four
loops
are
intended
for
four
different
usage
situations.
USER
loop
The
meter’s
configurable
display
loop,
which
is
intended
for
the
user.
The
readings
in
this
loop
can
be
adjusted
to
the
utility
company’s
requirements
via
the
DDD
‐
code.
See
paragraph
3.2.4
for
an
overview
of
possible
readings
in
the
meter’s
USER
loop.
The
same
paragraph
includes
examples
of
DDD
‐
codes.
TECH
loop
This
loop
is
intended
for
technicians
and
is
not
configurable.
The
loop
displays
all
the
meter’s
readings.
The
loop
includes
readings
like
serial
number,
date,
time,
config
number,
software
revision
and
segment
test.
See
paragraph
6.2
for
a
complete
overview
of
the
readings.
SETUP
loop
SETUP
loop
is
also
intended
for
the
technician.
In
this
loop
the
technician
can
configure
the
meter
via
the
front
keys.
In
general
(unless
otherwise
requested
by
the
customer)
the
loop
is
open
in
transport
state.
When
the
first
integration
has
been
carried
out
by
the
meter,
the
access
to
SETUP
loop
is
blocked.
From
now
on
it
is
no
longer
possible
to
access
SETUP
loop
unless
you
break
the
installation
seal.
See
paragraph
6.3
for
further
details
about
the
various
parameters
which
can
be
configured
in
SETUP
loop
and
see
paragraph
7.8
for
details
on
the
meter’s
transport
state.
TEST
loop
Used
by
authorized
laboratories
for
reverification
of
the
meter.
This
loop
is
not
available
unless
the
meter’s
test
seal
(verification
seal)
is
broken.